Dosimetric consequences of translational and rotational errors in frame-less image-guided radiosurgery
Open Access
- 24 April 2012
- journal article
- research article
- Published by Springer Nature in Radiation Oncology
- Vol. 7 (1) , 63
Abstract
To investigate geometric and dosimetric accuracy of frame-less image-guided radiosurgery (IG-RS) for brain metastases. Single fraction IG-RS was practiced in 72 patients with 98 brain metastases. Patient positioning and immobilization used either double- (n = 71) or single-layer (n = 27) thermoplastic masks. Pre-treatment set-up errors (n = 98) were evaluated with cone-beam CT (CBCT) based image-guidance (IG) and were corrected in six degrees of freedom without an action level. CBCT imaging after treatment measured intra-fractional errors (n = 64). Pre- and post-treatment errors were simulated in the treatment planning system and target coverage and dose conformity were evaluated. Three scenarios of 0 mm, 1 mm and 2 mm GTV-to-PTV (gross tumor volume, planning target volume) safety margins (SM) were simulated. Errors prior to IG were 3.9 mm ± 1.7 mm (3D vector) and the maximum rotational error was 1.7° ± 0.8° on average. The post-treatment 3D error was 0.9 mm ± 0.6 mm. No differences between double- and single-layer masks were observed. Intra-fractional errors were significantly correlated with the total treatment time with 0.7mm±0.5mm and 1.2mm±0.7mm for treatment times ≤23 minutes and >23 minutes (p5% in 14% of the patients. A 1 mm safety margin fully compensated intra-fractional patient motion. IG-RS with online correction of translational errors achieves high geometric and dosimetric accuracy. Intra-fractional errors decrease target coverage and conformity unless compensated with appropriate safety margins.Keywords
This publication has 25 references indexed in Scilit:
- Frameless linac-based stereotactic radiosurgery (SRS) for brain metastases: analysis of patient repositioning using a mask fixation system and clinical outcomesRadiation Oncology, 2011
- Semi-robotic 6 degree of freedom positioning for intracranial high precision radiotherapy; first phantom and clinical resultsRadiation Oncology, 2010
- A clinical comparison of patient setup and intra-fraction motion using frame-based radiosurgery versus a frameless image-guided radiosurgery system for intracranial lesionsRadiotherapy and Oncology, 2010
- The geometric accuracy of frameless stereotactic radiosurgery using a 6D robotic couch systemPhysics in Medicine & Biology, 2009
- Evaluation of Image-Guided Positioning for Frameless Intracranial RadiosurgeryInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Time Dependence of Intrafraction Patient Motion Assessed by Repeat Stereoscopic ImagingInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Reliability of the Bony Anatomy in Image-Guided Stereotactic Radiotherapy of Brain MetastasesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2007
- Repositioning accuracy of fractionated stereotactic irradiation: assessment of isocentre alignment for different dental fixations by using sequential CT scanningRadiotherapy and Oncology, 2005
- Errors and margins in radiotherapySeminars in Radiation Oncology, 2004
- Radiation therapy oncology group: Radiosurgery quality assurance guidelinesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1993