An imprinted polymeric matrix containing DNA for electrochemical sensing of 2,4–dichlorophenoxyacetic acid
Authors:
- 19 November 2019
- journal article
- research article
- Published by Springer Nature in Microchimica Acta
- Vol. 186 (12) , 814
Abstract
The authors describe an electrochemical method for the determination of herbicide 2,4-dichlorophenoxyacetic acid (2,4-D). It is based on the use of a molecularly imprinted polymer (MIP) and of dsDNA as a bio-specific substance. The modified electrode was prepared by electropolymerization of ortho-phenylenediamine (oPD) in the presence of DNA and of 2,4-D (the template). The imprinted MIP was placed on a pencil graphite electrode (PGE) modified with chitosan and multiwalled carbon nanotubes (MWCNTs). The template was removed with 0.4 M NaOH. The interaction of DNA with 2,4-D leads to its adsorption on the electrode, and this increases the sensitivity and selectivity of the method. After rebinding 2,4-D, the decrease in the peak current of oxidation of iron(II) acting as an electrochemical redox probe was measured by differential pulse voltammetry (DPV). The current, typically measured at around 0.5 V, increases linearly in the 0.01 to 10 pM 2,4-D concentration range, and the detection limit is 4.0 fM. The method is highly selective for 2,4-D. The modified electrode was applied to quantify 2,4-D in spiked environmental water and soil samples and gave absolute recoveries varying from 91.5 to 109.0%.Keywords
This publication has 33 references indexed in Scilit:
- Electrochemical sensor for 2,4-dichlorophenoxy acetic acid using molecularly imprinted polypyrrole membrane as recognition elementMicrochimica Acta, 2010
- Development of a voltammetric sensor based on a molecularly imprinted polymer (MIP) for caffeine measurementElectrochimica Acta, 2010
- Sensitive and rapid detection of 2,4-dicholorophenoxyacetic acid in water samples by using evanescent wave all-fiber immunosensorBiosensors and Bioelectronics, 2008
- Preparation of a highly sensitive enzyme electrode using gold nanoparticles for measurement of pesticides at the ppt levelJournal of Environmental Monitoring, 2008
- A multichannel electrochemical detector coupled with an ELISA microtiter plate for the immunoassay of 2,4-dichlorophenoxyacetic acidSensors and Actuators B: Chemical, 2007
- Electrochemical determination of 2,4-D at a mercury electrodeAnalytica Chimica Acta, 2005
- The immunosensors for measurement of 2,4-dichlorophenoxyacetic acid based on electrochemical impedance spectroscopyBioelectrochemistry, 2004
- o-Phenylenediamine Electropolymerization by Cyclic Voltammetry Combined with Electrospray Ionization-Ion Trap Mass SpectrometryAnalytical Chemistry, 2003
- The specific immunochemical detection of 2,4-dichlorophenoxyacetic acid and 2,4,5-trichlorophenoxyacetic acid pesticides by amperometric cholinesterase biosensorsAnalytica Chimica Acta, 1997
- A multichannel immunochemical sensor for determination of 2,4-dichlorophenoxyacetic acidAnalytica Chimica Acta, 1995