The effect of low-viscosity cement on mantle morphology and femoral stem micromotion: A cadaver model with simulated blood flow
Open Access
- 1 January 2006
- journal article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 77 (4) , 607-616
Abstract
Limited data exist on the performance of low-viscosity cement in clinically realistic cadaver models. Paired stem/cement/femur constructs were generated with low-viscosity and standard-viscosity cements. The constructs were created and tested under simulated in vivo conditions, for which novel techniques were developed during this study. Mantle function was quantified by stem/cortex micromotions over 105cycles of "stair-climbing". Mantle morphology was determined from transverse sections. Penetration of low-viscosity cement was greater proximally but less distally (p = 0.02). Low-viscosity cement resulted in more stem retroversion (p = 0.04), but there was no difference in subsidence (p = 0.4). Low-viscosity cement mantles had greater fractions of non-apposed interface (p = 0.006). Fraction of non-apposed interface predicted stem retroversion (R2 = 0.64, p = 0.002). Low-viscosity cement resulted in inferior cement mantles. Early micromotion was reduced by better interface apposition. The greater stem retroversion of low-viscosity cement would probably lead to higher revision rates. Early stem migration is due to interface non-apposition. Techniques should be developed to reduce non-apposition of cemented interfaces.Keywords
This publication has 18 references indexed in Scilit:
- Cement-implant interface gaps explain the poor results of CMW3 for femoral stem fixationActa Orthopaedica, 2005
- Influence of Cement Technique on the Interface Strength of Femoral ComponentsClinical Orthopaedics and Related Research, 2000
- Cement Pressurisation During Hip ReplacementThe Journal of Bone and Joint Surgery. British volume, 1997
- Tensile strength of the cement-bone interface depends on the amount of bone interdigitated with PMMA cementJournal of Biomechanics, 1997
- Cement viscosity affects the bone‐cement interface in total hip arthroplastyJournal of Orthopaedic Research, 1996
- Circulating blood diminishes cement penetration into cancellous bone:In vivo studies of 21 arthrotic femoral headsActa Orthopaedica, 1995
- Stem curvature and load angle influence the initial relative bone‐implant motion of cementless femoral stemsJournal of Orthopaedic Research, 1993
- Low-vs high-viscosity cement in hip arthroplasty: No radiographic difference in 226 arthrosis cases followed for 5 yearsActa Orthopaedica, 1993
- The Influence of Cementing Technique and Blood on the Strength of the Bone-Cement InterfaceEngineering in Medicine, 1988
- Penetration of Acrylic Bone Cements into Cancellous BoneActa Orthopaedica, 1983