Alternative methodology for linear polarization resistance assessment of reinforced concrete structure
Open Access
- 31 October 2018
- journal article
- research article
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 199, 06009
Abstract
For reinforced concrete structures, several corrosion detection methods exist: concrete resistivity, half-cell potential or linear polarization resistance (LPR) measurement. The LPR value can be linked to the corrosion rate thanks the Stern-Geary equation if strong hypotheses are made. Existing commercial devices use a guard ring to canalize the current on specific steel rebar area and assume that the steel rebar is uniformly polarized. However, recent works reveal that the top part of the steel rebar, right under the counter electrode, is the most polarized point. The particular point is referred as the point of interest (PI). This works belongs to the DIAMOND project which aims to produce a new corrosion rate measurement device. Comsol® software was used to model the influence of concrete cover, resistivity and injected current on the current density at the PI. Moreover, a significant influence of the steel rebars diameter was also demonstrated. Two types of abacus are built. The first one links to polarization measured on the surface to the polarization on the rebar at the PI. The second links the ratio between the current density at the PI and the density of injected current to concrete cover and steel rebar diameter. The Stern-Geary equation can now be used at the PI without using the approximation of a uniformly polarized rebar. The corrosion state of reinforced concrete structure can be controlled more precisely. The methodology is then applied on two concrete slabs in which three metal bars are embedded at different concrete covers. The first slab is prepared with ordinary concrete while the second contain chloride to artificially activate the corrosion process. The results reveal that the rebars embedded on the first slab are not corroding (icorr ≤0.2 μΑ/cm2) while the second rebar are corroding (icorr>0.2 μΑ/cm2).Keywords
This publication has 20 references indexed in Scilit:
- Probabilistic evaluation method for corrosion risk of steel reinforcement based on concrete resistivityConstruction and Building Materials, 2017
- Two-point concrete resistivity measurements: interfacial phenomena at the electrode–concrete contact zoneMeasurement Science and Technology, 2015
- Determination of the distribution of electrical resistivity in reinforced concrete structures using electrical resistivity tomographyMaterials and Corrosion, 2014
- Practical model for predicting corrosion rate of steel reinforcement in concrete structuresConstruction and Building Materials, 2014
- Measuring the corrosion rate of steel in concrete – effect of measurement technique, polarisation time and currentMaterials and Corrosion, 2010
- A framework for use of durability indexes in performance-based design and specifications for reinforced concrete structuresMaterials and Structures, 2007
- A practical method for calculating the corrosion rate of uniformly depassivated reinforcing bars in concreteMaterials and Corrosion, 2007
- Corrosion rate evolution in concrete structures exposed to the atmosphereCement and Concrete Composites, 2002
- Corrosion of reinforcing steel evaluated by means of concrete resistivity measurementsCorrosion Science, 2002
- On-site measurements of corrosion rate of reinforcementsConstruction and Building Materials, 2001