The fluence rate (FR) distribution in an ultraviolet (UV) reactor was determined experimentally in situ by use of a novel 360° micro fluorescent silica detector (MFSD). The UV response of the MFSD was systematically characterized, and the results indicated that this detector responded only to UV in the range from 210 to 280 nm. The nonlinearity was found to be less than 1% as the FR varied from 0.083 to 2110 μW/cm2. The luminescent signal increased by 0.11% for every degree increase in temperature in the studied range of 0−55 °C. FR distribution tests were performed in different media (air or water) with the water transmittance at either 95% or 85% determined in a 1-cm path length. The FR distribution of the near-lamp region (e.g., radius <50 mm) was well determined with the nearest distance to the sleeve being less than 3 mm. Comparisons were made between the experimental data and the calculations by use of the UVCalc model. This work demonstrates that the MFSD is a novel technique that can provide in situ and real-time measurements of the FR distribution in a UV reactor.Keywords
This publication has 21 references indexed in Scilit:
- Radiation field modeling of multi-lamp, homogeneous photoreactorsJournal of Photochemistry and Photobiology A: Chemistry, 2008
- Validation of large-scale, monochromatic UV disinfection systems for drinking water using dyed microspheresWater Research, 2008
- The lodide/lodate Actinometer in UV Disinfection: Determination of the Fluence Rate Distribution in UV ReactorsPhotochemistry and Photobiology, 2006
- Spectral Sensitivity of Bacillus subtilis Spores and MS2 Coliphage for Validation Testing of Ultraviolet Reactors for Water DisinfectionEnvironmental Science & Technology, 2005
- Impact of lamp shadowing and reflection on the fluence rate distribution in a multiple low-pressure UV lamp arrayWater Research, 2005
- Numerical modelling of UV intensity: Application to collimated-beam reactors and continuous-flow systemsWater Research, 1997
- Photoinduced conversion of optically active defects in germanium-doped silicaPhysical Review B, 1996
- Radiation profiles in an empty annular photoreactor with a source of finite spatial dimensionsAIChE Journal, 1973
- Spectrophotometer Linearity Testing Using the Double-Aperture MethodApplied Optics, 1972
- Light intensity profiles in a perfectly mixed photoreactorAIChE Journal, 1970