High resolution pituitary gland MRI at 7.0 tesla: a clinical evaluation in Cushing’s disease
Open Access
- 20 May 2015
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 26 (1) , 271-277
Abstract
Objective To evaluate the detection of pituitary lesions at 7.0 T compared to 1.5 T MRI in 16 patients with clinically and biochemically proven Cushing’s disease. Methods In seven patients, no lesion was detected on the initial 1.5 T MRI, and in nine patients it was uncertain whether there was a lesion. Firstly, two readers assessed both 1.5 T and 7.0 T MRI examinations unpaired in a random order for the presence of lesions. Consensus reading with a third neuroradiologist was used to define final lesions in all MRIs. Secondly, surgical outcome was evaluated. A comparison was made between the lesions visualized with MRI and the lesions found during surgery in 9/16 patients. Results The interobserver agreement for lesion detection was good at 1.5 T MRI (κ = 0.69) and 7.0 T MRI (κ = 0.62). In five patients, both the 1.5 T and 7.0 T MRI enabled visualization of a lesion on the correct side of the pituitary gland. In three patients, 7.0 T MRI detected a lesion on the correct side of the pituitary gland, while no lesion was visible at 1.5 T MRI. Conclusion The interobserver agreement of image assessment for 7.0 T MRI in patients with Cushing’s disease was good, and lesions were detected more accurately with 7.0 T MRI. Key Points • Interobserver agreement for lesion detection on 1.5 T MRI was good; • Interobserver agreement for lesion detection on 7.0 T MRI was good; • 7.0 T enabled confirmation of unclear lesions at 1.5 T; • 7.0 T enabled visualization of lesions not visible at 1.5 T.Keywords
This publication has 31 references indexed in Scilit:
- Ultrahigh-Field Magnetic Resonance Imaging: The Clinical Potential for Anatomy, Pathogenesis, Diagnosis, and Treatment Planning in Brain DiseaseNeuroimaging Clinics Of North America, 2012
- Predictive value of preoperative magnetic resonance imaging of the pituitary for surgical cure in cushing’s diseaseTurkish Neurosurgery, 2012
- Pre- and postoperative magnetic resonance imaging appearance of the normal residual pituitary gland following macroadenoma resection: Clinical implicationsSurgical Neurology International, 2012
- 7‐T MR—from research to clinical applications?NMR in Biomedicine, 2011
- Initial experience of 3 Tesla versus conventional field strength magnetic resonance imaging of small functioning pituitary tumoursClinical Endocrinology, 2011
- Preliminary Experience with 3-Tesla MRI and Cushing's DiseaseJournal of Neurological Surgery Part B: Skull Base, 2007
- The value of high-field MRI (3T) in the assessment of sellar lesionsEuropean Journal of Radiology, 2005
- Application of three-tesla magnetic resonance imaging for diagnosis and surgery of sellar lesionsJournal of Neurosurgery, 2004
- Dynamic contrast‐enhanced MR imaging of the pituitary gland with fast spin‐echo techniqueJournal of Magnetic Resonance Imaging, 1994
- Comparison of computerized tomography and magnetic resonance imaging for the examination of the pituitary gland in patients with Cushing's diseaseClinical Endocrinology, 1993