Presurgical Evaluation: Current Role of Invasive EEG
Authors:
Open Access
Abstract
Summary: Our purpose was to review the current role of invasive and semi‐invasive EEG in the presurgical evaluation of candidates for epilepsy surgery. The use of stereotactically implanted intracranial depth (stereo‐EEG), subdural strip and grid, and foramen ovale electrodes, as well as intraoperative electrocorticography and electrical brain stimulation (“functional mapping”) at the Epilepsy Center University Hospital Zurich, from 1984 to 1998, is analyzed. Advantages and disadvantages of the various intracranial EEG techniques are critically discussed. Out of 422 selective amygdalohippocampectomies performed in Zurich, 54% had non‐invasive, 32% had semi‐invasive, and 14% had invasive presurgical EEG evaluation. Because patients currently referred to our center increasingly present with a complex history of disease, i.e., constitute so‐called “difficult cases”, there is trend to combine several invasive and semi‐invasive, pre‐ and intraoperative neurophysiological techniques.Keywords
This publication has 9 references indexed in Scilit:
- Intraoperative validation of functional magnetic resonance imaging and cortical reorganization patterns in patients with brain tumors involving the primary motor cortexJournal of Neurosurgery, 1999
- Electroencephalograms in epilepsy: analysis and seizure prediction within the framework of Lyapunov theoryPhysica D: Nonlinear Phenomena, 1999
- Epileptologisches Outcome der Zürcher Amygdala-Hippokampektomie-SerieSchweizer Archiv für Neurologie und Psychiatrie, 1999
- The Anterior and Posterior Selective Temporal Lobe Amobarbital Tests: Angiographic, Clinical, Electroencephalographic, PET, SPECT Findings, and Memory PerformanceBrain and Cognition, 1997
- Activation of the epileptic focus during intracarotid amobarbital test. Electrocorticographic registration via subdural electrodesElectroencephalography and Clinical Neurophysiology, 1990
- The intracarotid amobarbital procedure as a predictor of memory failure following unilateral temporal lobectomyNeurology, 1990
- Improved multipolar foramen ovale electrode monitoringJournal of Epilepsy, 1988
- The ‘foramen ovale electrode’: a new recording method for the preoperative evaluation of patients suffering from mesio-basal temporal lobe epilepsyElectroencephalography and Clinical Neurophysiology, 1985
- Effects of amobarbital and methohexital on epileptic activity in mesial temporal structures in epileptic patients. An EEG study with depth electrodesActa Neurologica Scandinavica, 1984