The use of dried blood spot sampling for the measurement of HbA1c: a cross-sectional study
Open Access
- 8 July 2015
- journal article
- research article
- Published by Springer Nature in BMC Clinical Pathology
- Vol. 15 (1) , 1-7
Abstract
The use of dried blood spot (DBS) sampling is an alternative to traditional venous blood collection, and particularly useful for people living in rural and remote areas, and for those who are infirm, house-bound or time-poor. The objective of this study was to assess whether the measurement of glycated haemoglobin A1c (HbA1c) in DBS samples provided comparative and acceptably precise results. Venous and capillary blood samples were collected from 115 adult participants. After proper instruction, each participant punctured his/her own finger and collected capillary blood samples on pieces of a proprietary cellulose filter paper. Each filter paper was subsequently placed inside a breathable envelope, stored at room temperature, and processed on the same day (D0), four (D4), seven (D7) and fourteen (D14) days after collection. HbA1c was measured in duplicates/triplicates in whole venous blood (WB), capillary blood (capDBS) and venous blood placed on the matrix paper (venDBS), by turbidimetric inhibition immunoassay. Intra-assay coefficients of variation (CV) were calculated. DBS values were compared to WB results using linear regression, Bland-Altman plots and cross-validation models. Eleven and 56 patients had type 1 and type 2 diabetes mellitus, respectively. Mean HbA1c levels were 6.22 ± 1.11 % for WB samples (n = 115). The median intra-assay CV was lower than 3 % for WB and capDBS on all days. Results from capDBS and venDBS showed high correlation and agreement to WB results, with narrow 95 % limits of agreement (except for results from D14 samples), as observed in Bland-Altman plots. When capDBS values were applied to equations derived from regression analyses, results approached those of WB values. A cross-validation model showed that capDBS results on D0, D4 and D7 were close to the WB results, with prediction intervals that were narrow enough to be clinically acceptable. The measurement of HbA1c from DBS samples provided results that were comparable to results from WB samples, if measured up to seven days after collection. Intra-assay coefficients of variation were low, results were in agreement with the gold-standard, and prediction intervals were clinically acceptable. The measurement of HbA1c through DBS sampling may be considered in situations where traditional venipuncture is not available. Australian New Zealand Clinical Trials Registry ID ACTRN12613000769785 .Keywords
This publication has 24 references indexed in Scilit:
- Comparison of dried blood spot to venous methods for hemoglobin A1c, glucose, total cholesterol, high-density lipoprotein cholesterol, and C-reactive proteinClinica Chimica Acta, 2013
- Measurement of Hemoglobin A1c from Filter Papers for Population-Based StudiesClinical Chemistry, 2011
- Blood spots as an alternative to whole blood collection and the effect of a small monetary incentive to increase participation in genetic association studiesBMC Medical Research Methodology, 2009
- The Use of Dried Blood Spot Sampling in the National Social Life, Health, and Aging ProjectThe Journals of Gerontology, Series B: Psychological Sciences and Social Sciences, 2009
- HbA1c measurements from dried blood spots: validation and patient satisfactionClinical Chemistry and Laboratory Medicine (CCLM), 2009
- Dried blood spots as a source of anti-malarial antibodies for epidemiological studiesMalaria Journal, 2008
- Newborn screeningPathology, 2008
- Stability of haemoglobin A1c (HbA1c) measurements from frozen whole blood samples stored for over a decadeDiabetic Medicine, 2005
- Capillary Blood on Filter Paper for Determination of HbA1c by Ion Exchange ChromatographyDiabetes Care, 1996
- Accuracy of a Filter Paper Method for Measuring Glycosylated HemoglobinDiabetes Care, 1992