Cycle‐consistent adversarial denoising network for multiphase coronary CT angiography
Authors:
Top Cited Papers
- 17 November 2018
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 46 (2) , 550-562
Abstract
Purpose: In multiphase coronary CT angiography (CTA), a series of CT images are taken at different levels of radiation dose during the examination. Although this reduces the total radiation dose, the image quality during the low‐dose phases is significantly degraded. Recently, deep neural network approaches based on supervised learning technique have demonstrated impressive performance improvement over conventional model‐based iterative methods for low‐dose CT. However, matched low‐ and routine‐dose CT image pairs are difficult to obtain in multiphase CT. To address this problem, we aim at developing a new deep learning framework.Method: We propose an unsupervised learning technique that can remove the noise of the CT images in the low‐dose phases by learning from the CT images in the routine dose phases. Although a supervised learning approach is not applicable due to the differences in the underlying heart structure in two phases, the images are closely related in two phases, so we propose a cycle‐consistent adversarial denoising network to learn the mapping between the low‐ and high‐dose cardiac phases.Results: Experimental results showed that the proposed method effectively reduces the noise in the low‐dose CT image while preserving detailed texture and edge information. Moreover, thanks to the cyclic consistency and identity loss, the proposed network does not create any artificial features that are not present in the input images. Visual grading and quality evaluation also confirm that the proposed method provides significant improvement in diagnostic quality.Conclusions: The proposed network can learn the image distributions from the routine‐dose cardiac phases, which is a big advantage over the existing supervised learning networks that need exactly matched low‐ and routine‐dose CT images. Considering the effectiveness and practicability of the proposed method, we believe that the proposed can be applied for many other CT acquisition protocols.Keywords
All Related Versions
Funding Information
- Ministry of Trade, Industry and Energy
- National Research Council of Science and Technology (CAP‐13‐3‐KERI)
This publication has 26 references indexed in Scilit:
- Deep Convolutional Framelet Denosing for Low-Dose CT via Wavelet Residual NetworkIEEE Transactions on Medical Imaging, 2018
- A deep convolutional neural network using directional wavelets for low‐dose X‐ray CT reconstructionMedical Physics, 2017
- Low-Dose CT With a Residual Encoder-Decoder Convolutional Neural NetworkIEEE Transactions on Medical Imaging, 2017
- Iterative reconstruction methods in X-ray CTPhysica Medica, 2012
- A Splitting-Based Iterative Algorithm for Accelerated Statistical X-Ray CT ReconstructionIEEE Transactions on Medical Imaging, 2011
- Evaluation of Heavily Calcified Vessels with Coronary CT Angiography: Comparison of Iterative and Filtered Back Projection Image ReconstructionRadiology, 2011
- Combination of a Low-Tube-Voltage Technique With Hybrid Iterative Reconstruction (iDose) Algorithm at Coronary Computed Tomographic AngiographyJournal of Computer Assisted Tomography, 2011
- Adaptive Statistical Iterative Reconstruction: Assessment of Image Noise and Image Quality in Coronary CT AngiographyAmerican Journal of Roentgenology, 2010
- Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimizationPhysics in Medicine & Biology, 2008
- Prior image constrained compressed sensing (PICCS): A method to accurately reconstruct dynamic CT images from highly undersampled projection data setsMedical Physics, 2008