Fluorophore-mediated, fiber-optic, multi-analyte, immunosensing system for rapid diagnosis and prognosis of cardiovascular diseases
Authors:
- 1 January 2006
- journal article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 11 (2) , 021011-021011-10
Abstract
A prototype of a fiber-optic, multi-analyte, immunobiosensing system was developed to simultaneously quantify disease-representing biomarkers in blood plasma. This system was for simultaneous quantification of two different groups of multi-biomarkers related to cardiovascular diseases (CVD): anticoagulants (protein C, protein S, antithrombin III, and plasminogen) for deficiency diagnosis; and cardiac markers (B-type natriuretic peptide, cardiac troponin I, myoglobin, and C-reactive protein) for coronary heart disease diagnosis. As an initial effort towards the development of a disposable and easy-to-use sensing cartridge as a rapid diagnostic tool for CVD related diseases, a prototype of a flow control system was also developed to automatically perform simultaneous four-analyte quantification. Currently, the system is capable of quantifying the multiple anticoagulants in their clinically significant sensing ranges within 5 minutes, at an average signal-to-noise (S∕N) ratio of 25. A simultaneous assay of the four cardiac markers can be performed within 10 min, at an average S∕N ratio of 20. When this highly portable multi-analyte sensing system is completed and successfully tested for CVD patient’s plasma, it can provide rapid and reliable diagnostic and prognostic information at a patient’s bedside.
Keywords
This publication has 31 references indexed in Scilit:
- Theoretical and experimental analysis of analyte transport in a fiber‐optic, protein C immuno‐biosensorBiotechnology and Bioengineering, 2004
- Rapid Measurement of B-Type Natriuretic Peptide in the Emergency Diagnosis of Heart FailureThe New England journal of medicine, 2002
- Multimarker Approach to Risk Stratification in Non-ST Elevation Acute Coronary SyndromesCirculation, 2002
- Preliminary study of real-time fiber optic based protein C biosensorBiotechnology and Bioengineering, 1999
- Familial thrombophilia: genetic risk factors and managementJournal of Internal Medicine, 1997
- A comparison of three fluorophores for use in an optical biosensor for the measurement of prostate-specific antigen in whole bloodSensors and Actuators B: Chemical, 1995
- Measurement of Free Phenytoin in Blood with a Self-Contained Fiber-Optic ImmunosensorAnalytical Chemistry, 1994
- Fiber-Optic Biosensor for the Detection of Hazardous MaterialsImmunoMethods, 1993
- Ischemic stroke due to deficiency of coagulation inhibitors. Report of 10 young adults.Stroke, 1993
- A Population-Based Perspective of the Hospital Incidence and Case-Fatality Rates of Deep Vein Thrombosis and Pulmonary EmbolismArchives of internal medicine (1960), 1991