Evaluation of an in-house enzyme-linked immunosorbent assay for quantitative measurement of serum total thyroxine concentration in dogs and cats
Authors:
- Ellen N. BehrendEBEllen N. Behrend
- Robert J. KemppainenRKRobert J. Kemppainen
- 15 July 2002
- journal article
- research article
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 221 (2) , 243-249
Abstract
Objective—To compare serum total thyroxine (T4) concentrations obtained with an in-house ELISA and a validated radioimmunoassay (RIA). Design—Laboratory trial. Sample Population—50 canine and 50 feline serum samples submitted for measurement of total T4 concentration with the RIA; samples were selected to represent a wide range of concentrations (< 6 to 167 nmol/L). Procedure—Results of the ELISA and RIA were compared by calculating correlation coefficients, examining linearity, determining bias and precision, and evaluating clinical interpretations. Results—Correlation coefficients for results of the 2 methods were 0.84 for the canine samples and 0.59 for the feline samples. Examination of bias plots revealed large variations in ELISA results, compared with RIA results. For the feline samples, the ELISA consistently overestimated total T4 concentration obtained with the RIA. When results of the 2 methods were categorized (low, borderline low, normal, borderline high, or high), results were discordant for 24 (48%) and 29 (58%) of the canine samples and for 18 (36%) and 28 (56%) of the feline samples (depending on whether borderline high ELISA results were considered normal or high). Reliance on results of the ELISA would have led to inappropriate clinical decisions for 31 (62%) canine samples and 25 (50%) feline samples. The ELISA coefficients of variation for the pooled canine and feline samples were 18 and 28%, respectively. Conclusions and Clinical Relevance—Substantial discrepancies between ELISA and RIA results for T4 concentrations were detected. Thus, we concluded that the in-house ELISA kit was not accurate for determining serum total T4 concentrations in dogs and cats. (J Am Vet Med Assoc 2002;221:243–249)Keywords
This publication has 24 references indexed in Scilit:
- Thyrotropin-Releasing Hormone Stimulation Test to Assess Thyroid Function in Severely Sick CatsJournal of Veterinary Internal Medicine, 2001
- Is it possible to diagnose canine hypothyroidism?Journal of Small Animal Practice, 1999
- Serum free thyroxine concentrations measured by chemiluminescence in hyperthyroid and euthyroid catsJournal of the American Animal Hospital Association, 1996
- Use of the Thyrotropin Releasing Hormone Stimulation Test to Diagnose Mild Hyperthyroidism in CatsJournal of Veterinary Internal Medicine, 1994
- Etiopathogenesis of Canine HypothyroidismVeterinary Clinics of North America: Small Animal Practice, 1994
- Method Comparison—A Different ApproachAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1992
- The Cusum Test with Ols ResidualsEconometrica, 1992
- Triiodothyronine (T3) Suppression TestJournal of Veterinary Internal Medicine, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Evidence for episodic but not circadian activity in plasma concentrations of adrenocorticotrophin, cortisol and thyroxine in dogsJournal of Endocrinology, 1984