The assessment of a drug’s cardiac liability has undergone considerable metamorphosis by regulators since International Council for Harmonization of Technical Requirement for Pharmaceuticals for Human Use E14 guideline was introduced in 2005. Drug developers now have a choice in how proarrhythmia risk can be evaluated; the options include a dedicated thorough QT (TQT) study or exposure response (ER) modeling of intensive electrocardiogram (ECG) captured in early clinical development. The alternative approach of ER modeling was incorporated into a guidance document in 2015 as a primary analysis tool which could be utilized in early phase dose escalation studies as an option to perform a dedicated TQT trial. This review will describe the current state of ER modeling of intensive ECG data collected during early clinical drug development; the requirements with regard to the use of a positive control; and address the challenges and opportunities of this alternative approach to assessing QT liability.Keywords
This publication has 41 references indexed in Scilit:
- Estimation of the Power of the Food Effect on QTc to Show Assay SensitivityThe Journal of Clinical Pharmacology, 2018
- Electrocardiographic Biomarkers for Detection of Drug-Induced Late Sodium Current BlockPLOS ONE, 2016
- Cardiovascular Safety Assessment in Early‐Phase Clinical Studies: A Meta‐Analytical Comparison of Exposure‐Response ModelsCPT: Pharmacometrics & Systems Pharmacology, 2016
- Can Bias Evaluation Provide Protection Against False‐Negative Results in QT Studies Without a Positive Control Using Exposure‐Response Analysis?The Journal of Clinical Pharmacology, 2016
- Evolution of strategies to improve preclinical cardiac safety testingNature Reviews Drug Discovery, 2016
- Single Doses up to 800 mg of E-52862 Do Not Prolong the QTc Interval – A Retrospective Validation by Pharmacokinetic-Pharmacodynamic Modelling of Electrocardiography Data Utilising the Effects of a Meal on QTc to Demonstrate ECG Assay SensitivityPLOS ONE, 2015
- The reproducibility of QTc changes after meal intakeJournal of Electrocardiology, 2015
- Evaluating the Use of Linear Mixed‐Effect Models for Inference of the Concentration‐QTc Slope Estimate as a Surrogate for a Biological QTc ModelCPT: Pharmacometrics & Systems Pharmacology, 2015
- The Cost-Effectiveness of Drug Regulation: The Example of Thorough QT/QTc StudiesClinical Pharmacology & Therapeutics, 2011
- Sertindole causes distinct electrocardiographic T-wave morphology changesEuropean Neuropsychopharmacology, 2009