Abstract
Background: Robotic assistance is considered capable of improving precision and outcomes of total knee replacement. We assessed the inherent biases, pre-procedural planning accuracy using 2D to 3D X-Atlas®, and final knee axis outcomes of the ROSA® Knee System (Zimmer Biomet, Warsaw, IN, USA). Methods: A total of 55 patients who underwent robotic-assisted knee replacement using ROSA® Knee System (Zimmer Biomet, Warsaw, IN, USA) at a single center were included. Pre-procedural measurements performed by ROSA were compared to those performed by senior consultants. Component sizes predicted by ROSA® were compared to those implanted. A final axis measurement was taken during the procedure. Results: Femur components were exactly matched in (83.64%) cases, accurately matched in a further 8 (14.55%), and inaccurately matched for only 1 (1.82%). Tibial component sizes were exactly matched by the planning for 39 (70.91%), accurately for 12 (21.82%), and inaccurately for 4 (7.27%). ANOVA did not show statistically significant differences between the predicted and implanted femur (p = 0.96) nor the tibia components (p = 0.27). We show that ROSA® pre-procedural planning has a statistically significant bias (p = 0.001), with a deviation of 0.83 degrees into varus, when assessing the knee axis in the coronal plane, compared to senior consultant measurements. The average of the final coronal knee axis was 0.37 degrees in varus (SD = 2.49). Conclusions: ROSA® accurately predicts implanted component sizes. Despite the small and statistically significant varus bias in initial knee axis assessment, the system results lay within the ±3° of neutral knee axis, which is the widely accepted knee replacement standard.Keywords
This publication has 11 references indexed in Scilit:
- Robotic assisted versus conventional total knee arthroplasty: a systematic review and meta-analysis of randomised controlled trialsJournal of Robotic Surgery, 2024
- Accuracy and Outcomes of a Novel Cut-Block Positioning Robotic-Arm Assisted System for Total Knee Arthroplasty: A Systematic Review and Meta-AnalysisArthroplasty Today, 2024
- Comparable results in total knee arthroplasty using the ROSA knee system versus the conventional technique: A retrospective propensity‐matched cohort studyKnee Surgery, Sports Traumatology, Arthroscopy, 2024
- Comparison of Alignment Accuracy and Clinical Outcomes between a CT‐Based, Saw Cutting Robotic System and a CT‐Free, Jig‐guided Robotic System for Total Knee ArthroplastyOrthopaedic Surgery, 2024
- Robotic‐assisted total knee arthroplasty is not associated with improved accuracy in implant position and alignment compared to conventional instrumentation in the execution of a preoperative digital planJournal of Experimental Orthopaedics, 2024
- Increased Accuracy in Templating for Total Knee Arthroplasty Using 3D Models Generated from RadiographsThe Journal of Knee Surgery, 2022
- Robotic-assisted total knee arthroplasty improves the outlier of rotational alignment of the tibial prosthesis using 3DCT measurementsThe Knee, 2021
- Radiological assessment of lower limb alignmentEFORT Open Reviews, 2021
- Overhang of the Femoral Component in Total Knee Arthroplasty: Risk Factors and Clinical ConsequencesJournal of Bone and Joint Surgery, 2010
- Coronal alignment after total knee replacementThe Journal of Bone and Joint Surgery. British volume, 1991