The use of poly(acrylamide-acrylic acid)-montmorillonite composite for preparing low-activity 60Co, 65Zn, 134,137Cs mixed sealed source for radiometric calibration purposes
- 1 May 2012
- journal article
- Published by Pleiades Publishing Ltd in Radiochemistry
- Vol. 54 (3) , 269-273
Abstract
Poly(acrylamide-acrylic acid)-montmorillonite composite [P(AAm-MA)-M] was synthesized and used for preparing 60Co, 65Zn, 134,137Cs mixed sealed source. The synthesis procedure was based on γ-induced polymerization of polyacrylamide (PAAm) in the presence of acrylic acid (AA), clay minerals (montmorillonite, M), and N,N′-methylenebisacrylamide (NMBA) as a cross-linker. The adsorbent functionality was assayed using FTIR spectroscopy and thermal analysis. The distribution coefficients of 60Co(II), 65Zn(II), and 134,137Cs(I) ions on P(AAm-MA)-M were determined in relation to HCl concentration. P(AAm-MA)-M was loaded with 60Co, 65Zn, and 134,137Cs by equilibrating it (0.5 g) with a mixed solution of 60Co, 65Zn, and 134,137Cs at pH 3 (HCl) for 24 h at 25 ± 1°C. Mixed sealed source containing 5.3, 0.03, 0.05, and 1.05 μCi of 60Co, 65Zn, 134Cs, and 137Cs, respectively, was prepared by packing 100 mg of the loaded matrix in the cylindrical cavity of a Chinese Artelone capsule. The sealed source was subjected to quality control tests.Keywords
This publication has 14 references indexed in Scilit:
- Preparation of 65Zn and 134Cs sealed sources based on commercial organic and synthesized inorganic sorbents for calibration purposes of γ-detectorsApplied Radiation and Isotopes, 2009
- Preparation of 137Cs and 60Co sealed sources based on inorganic sorbents for radiometric calibration purposesColloids and Surfaces A: Physicochemical and Engineering Aspects, 2008
- Freeze-drying applied to radioactive source preparationApplied Radiation and Isotopes, 2004
- A novel approach for the adsorption of iodine-125 on silver wire as matrix for brachytherapy source for the treatment of eye and prostate cancerApplied Radiation and Isotopes, 2002
- Absolute measurement of 166mHo radioactivity and development of sealed sources for standardization of γ-ray emitting nuclidesApplied Radiation and Isotopes, 2000
- Conditions of use for sealed cobalt 60 sourcesRadiation Physics and Chemistry, 2000
- Composite sorbents of inorganic ion-exchangers and polyacrylonitrile binding matrixJournal of Radioanalytical and Nuclear Chemistry, 1997
- Feasibility study of a portable PIXE system using a210Po alpha sourceNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1996
- Preparation of electrodeposited source for65ZnJournal of Radioanalytical and Nuclear Chemistry, 1996
- New method for preparation of a ceramic strontium-90 titanate β-ray sourceThe International Journal of Applied Radiation and Isotopes, 1975