A combined epicardial implantation and subsequent extraction strategy in pacemaker device infection in pacemaker‐dependent patients
- 23 May 2018
- journal article
- research article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 41 (8) , 906-911
Abstract
Introduction: Treatment infections is challenging in pacemaker (PM) dependent patients. We proposed a novel implantation strategy for this group of patients.Methods: Patients who were PM dependent and were admitted with a PM infection received a combined procedure of left ventricular (LV) epicardial implantation of a PM lead and subsequent extraction of the infected system. No temporary pacing wire was used and the PM generator was placed in the left flank.Results: Between 2012 and 2015 we treated 16 patients who were PM dependent and with a PM infection. The majority of patients were male (81% [13/16]) and the median age was 71 years (50–91). The cause of infection was valvular endocarditis in 38% (6/16), lead infection in 25% (4/16), and isolated pocket infection in 38% (6/16).All patients underwent epicardial implantation of a LV lead (1084T bipolar lead; St. Jude Medical Myodex, St. Paul, MN, USA) and extraction of the infected device. There was no occurrence of periprocedural mortality and no postprocedural tamponades. There was one complication in the form of a hemorrhage at the infected device extraction site. In the median follow‐up period of 17 months there were four of 16 deaths, none of which were attributable to epicardial LV implantation. LV‐lead threshold was 1.1V (±0.7V) upon implantation that increased to 1.2V (±0.6V) at 0.4‐ms pulse duration. There were no reinfections of the epicardial lead or device.Conclusion: Epicardial left ventricle PM implantation and subsequent extraction of an infected PM in PM‐dependent patients is feasible and safe with good long‐term outcome.Keywords
This publication has 24 references indexed in Scilit:
- Low Incidence of Livestock-Associated Methicillin-Resistant Staphylococcus aureus Bacteraemia in The Netherlands in 2009PLOS ONE, 2013
- The definition, classification, and prognosis of chronic kidney disease: a KDIGO Controversies Conference reportKidney International, 2011
- Update on Cardiovascular Implantable Electronic Device Infections and Their ManagementCirculation, 2010
- Contemporary management of and outcomes from cardiac device related infectionsEP Europace, 2009
- Risk Factors Related to Infections of Implanted Pacemakers and Cardioverter-DefibrillatorsCirculation, 2007
- Percutaneous Lead Implantation Connected to an External Device in Stimulation‐Dependent Patients with Systemic Infection—A Prospective and Controlled StudyPacing and Clinical Electrophysiology, 2006
- Surgical epicardial left ventricular lead versus coronary sinus lead placement in biventricular pacing☆European Journal of Cardio-Thoracic Surgery, 2005
- Comparison of left ventricular lead placement via the coronary venous approach versus lateral thoracotomy in patients receiving cardiac resynchronization therapyThe American Journal of Cardiology, 2004
- Increasing rates of cardiac device infections among medicare beneficiaries: 1990–1999American Heart Journal, 2004
- Regional survey of temporary transvenous pacing procedures and complicationsPostgraduate Medical Journal, 2003