Comparison of Hybrid and Pure Iterative Reconstruction Techniques With Conventional Filtered Back Projection
Authors:
- Sarabjeet SinghSSSarabjeet Singh
- Mannudeep K. KalraMKMannudeep K. Kalra
- Synho DoSDSynho Do
- Jean Baptiste ThibaultJTJean Baptiste Thibault
- Homer PienHPHomer Pien
- Owen O. J. ConnorOCOwen O. J. Connor
- Michael A. BlakeMBMichael A. Blake
- 1 January 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 36 (3) , 347-353
Abstract
Assess the effect of filtered back projection (FBP) and hybrid (adaptive statistical iterative reconstruction [ASIR]) and pure (model-based iterative reconstruction [MBIR]) iterative reconstructions on abdominal computed tomography (CT) acquired with 75% radiation dose reduction. In an institutional review board-approved prospective study, 10 patients (mean [standard deviation] age, 60 (8) years; 4 men and 6 women) gave informed consent for acquisition of additional abdominal images on 64-slice multidetector-row CT (GE 750HD, GE Healthcare). Scanning was repeated over a 10-cm scan length at 200 and 50 milliampere second (mA s), with remaining parameters held constant at 120 kilovolt (peak), 0.984:1 pitch, and standard reconstruction kernel. Projection data were deidentified, exported, and reconstructed to obtain 4 data sets (200-mA s FBP, 50-mA s FBP, 50-mA s ASIR, 50-mA s MBIR), which were evaluated by 2 abdominal radiologists for lesions and subjective image quality. Objective noise and noise spectral density were measured for each image series. Among the 10 patients, the maximum weight recorded was 123 kg, with maximum transverse diameter measured as 43.7 cm. Lesion conspicuity at 50-mA s MBIR was better than on 50-mA s FBP and ASIR images (P < 0.01). Image noise was rated as suboptimal on low-dose FBP and ASIR but deemed acceptable in MBIR images. Objective noise with 50-mA s MBIR was 2 to 3 folds lower compared to 50-mA s ASIR, 50-mA s FBP, and 200-mA s FBP (P < 0.0001). Noise spectral density analyses demonstrated that ASIR retains the noise spectrum signature of FBP, whereas MBIR has much lower noise with a more regularized noise spectrum pattern. Model-based iterative reconstruction renders acceptable image quality and diagnostic confidence in 50- mA s abdominal CT images, whereas FBP and ASIR images are associated with suboptimal image quality at this radiation dose level.Keywords
This publication has 13 references indexed in Scilit:
- Dose Reduction in Abdominal Computed TomographyInvestigative Radiology, 2011
- Adaptive Statistical Iterative Reconstruction Technique for Radiation Dose Reduction in Chest CT: A Pilot StudyRadiology, 2011
- Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experienceThe International Journal of Cardiovascular Imaging, 2010
- Abdominal CT: Comparison of Adaptive Statistical Iterative and Filtered Back Projection Reconstruction TechniquesRadiology, 2010
- Abdominal CT: Comparison of Low-Dose CT With Adaptive Statistical Iterative Reconstruction and Routine-Dose CT With Filtered Back Projection in 53 PatientsAmerican Journal of Roentgenology, 2010
- Fast Model-Based X-Ray CT Reconstruction Using Spatially Nonhomogeneous ICD OptimizationIEEE Transactions on Image Processing, 2010
- Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007Archives of internal medicine (1960), 2009
- MEDICAL RADIATION EXPOSURE IN THE U.S. IN 2006: PRELIMINARY RESULTSHealth Physics, 2008
- Application of the noise power spectrum in modern diagnostic MDCT: part I. Measurement of noise power spectra and noise equivalent quantaPhysics in Medicine & Biology, 2007
- Strategies for CT Radiation Dose OptimizationRadiology, 2004