A guanidinium ionic liquid-based surfactant as an adequate solvent to separate and preconcentrate cadmium and copper in water using in situ dispersive liquid–liquid microextraction
- 12 February 2018
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 10 (13) , 1529-1537
Abstract
An in situ dispersive liquid–liquid microextraction (DLLME) method together with flame atomic absorption spectroscopy (FAAS) is developed for the extraction and determination of copper and cadmium from aqueous samples using as an extraction solvent a low cytotoxic ionic liquid (IL)-based surfactant, specifically decylguanidinium chloride (C10Gu-Cl). The IL-based surfactant 1-hexadecyl-3-butylimidazolium bromide (C16C4Im-Br) is also used for comparative purposes. In the method, N,N′-bis(salicylidene)thiocarbohydrazide is the complexing agent, and the metathesis reaction in the in situ DLLME is accomplished using lithium bis[(trifluoromethyl)sulfonyl]imide. The main parameters affecting the extraction efficiency of the method, i.e. pH of the sample, NaCl content, and vortex time, are properly optimized with a Doehlert experimental design. The method using C10Gu-Cl exhibited a limit of detection (LOD) four times lower and with slightly better reproducibility than that of the imidazolium IL-based surfactant. The validation of the in situ DLLME-FAAS method with C10Gu-Cl is accomplished for the simultaneous extraction and quantification of copper and cadmium from water. The optimum method requires 10 mL of aqueous sample and ∼25 μL of the IL-based surfactant to obtain a microdroplet of ∼21 μL, which is diluted up to 120 μL with acetonitrile to perform the analytical determination of both metals. LODs down to 0.3 and 0.5 μg L−1 were reached with the entire in situ IL-DLLME-FAAS for copper and cadmium, respectively. The inter-day relative standard deviation values were lower than 17% for both metal ions; with relative recoveries of 97.8% and 102%, and enrichment factors of 85 and 94, for copper and cadmium, respectively, at a low spiked level (4 and 6 μg L−1, respectively). Furthermore, the developed method shows adequate precision and accuracy evaluated with a certified reference material, the absence of matrix effects, and high tolerance limits towards common cations (between 80 and 600) for the analysis of tap water, while accomplishing the requirements of green analytical chemistry.Keywords
Funding Information
- Ministerio de Economía y Competitividad (MAT2014-57465-R)
This publication has 44 references indexed in Scilit:
- Guanidinium vs. Ammonium Surfactants in Soft‐Templating Approaches: Nanostructured Silica and Zwitterionic i‐Silica from Complementary Precursor–Surfactant Ion PairsEuropean Journal of Inorganic Chemistry, 2012
- Determination of silver in real samples using homogeneous liquid-liquid microextraction based on ionic liquidJournal of Analytical Chemistry, 2011
- Synthesis, toxicity, biodegradability and physicochemical properties of 4-benzyl-4-methylmorpholinium-based ionic liquidsGreen Chemistry, 2011
- Preconcentration procedure using in situ solvent formation microextraction in the presence of ionic liquid for cadmium determination in saline samples by flame atomic absorption spectrometryTalanta, 2010
- Microextraction technique based on ionic liquid for preconcentration and determination of palladium in food additive, sea water, tea and biological samplesFood and Chemical Toxicology, 2010
- Luminescent Organic–Inorganic Hybrids of Functionalized Mesoporous Silica SBA-15 by Thio-Salicylidene Schiff BaseDiscover Nano, 2010
- In situ solvent formation microextraction based on ionic liquids: A novel sample preparation technique for determination of inorganic species in saline solutionsAnalytica Chimica Acta, 2009
- Interfacial and micellar properties of imidazolium-based monocationic and dicationic ionic liquidsColloids and Surfaces A: Physicochemical and Engineering Aspects, 2007
- Copper deficiency and neurological disorders in man and animalsBrain Research Reviews, 2007
- Doehlert matrix: a chemometric tool for analytical chemistry—reviewTalanta, 2004