Accuracy of lower cervical pedicle screw placement with assistance of distinct navigation systems: a human cadaveric study
Authors:
- 18 September 2012
- journal article
- Published by Springer Nature in European Spine Journal
- Vol. 22 (1) , 148-155
Abstract
Evaluate the accuracy of five different techniques for lower cervical pedicle screw placement. Forty human cadaveric cervical spines were equally divided into five groups, and each group had eight specimens. Pedicle screws with dia. 3.5 mm were used. Group 1 was blind screw placement without any assistance; Group 2–5 was assisted by the X-ray fluoroscopy, virtual fluoroscopy navigation system, CT-based navigation system, and Iso-C 3D navigation system, respectively. Thereafter, cortical integrity of each pedicle was evaluated by anatomic dissection of the specimens. A total of 398 pedicle screws were inserted. In the Group 1–5, the average operation time per sample was 27 ± 3.0, 112 ± 10.3, 69 ± 6.4, 98 ± 11.0, and 91 ± 6.0 min, respectively. The outcome for excellent, fair and poor were 29 (36.3 %), 21 (26.2 %) and 30 (37.5 %) in Group 1; 35 (44.9 %), 29 (37.2 %) and 14 (17.9 %) in Group 2; 34 (42.5 %), 36 (45.0 %) and 10 (12.5 %) in Group 3; 70 (87.5 %), 10 (12.5 %) and 0 (0.0 %) in Group 4; 72 (90.0 %), 8 (10.0 %) and 0 (0.0 %) in Group 5. Blind screw placement was surely unsafe. Lower cervical pedicle screw placement assisted by the CT-based navigation system or the Iso-C 3D navigation system significantly improved the accuracy compared to the fluoroscopy assistance and the virtual fluoroscopy navigation assistance.Keywords
This publication has 14 references indexed in Scilit:
- Posterior fixation and fusion of unstable Hangman’s fracture by using intraoperative three-dimensional fluoroscopy-based navigationEuropean Spine Journal, 2011
- Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5,992 pedicle screwsEuropean Spine Journal, 2010
- Cervical pedicle screw insertion using a computed tomography cutout techniqueJournal of Neurosurgery: Spine, 2009
- Image-guided spine surgery: state of the art and future directionsEuropean Spine Journal, 2009
- Radiation Exposure from Musculoskeletal Computerized Tomographic ScansJournal of Bone and Joint Surgery, 2009
- Biomechanical Pullout Strength and Stability of the Cervical Artificial Pedicle ScrewSpine, 2009
- Pedicle screw fixation in the cervical spine.2008
- Pedicle Screw Placement AccuracySpine, 2007
- Randomized Clinical Study to Compare the Accuracy of Navigated and Non-Navigated Thoracic Pedicle Screws in Deformity Correction SurgeriesSpine, 2007
- Complications of Pedicle Screw Fixation in Reconstructive Surgery of the Cervical SpineSpine, 2000