Six-phase induction machine drive model for fault-tolerant operation

Authors:

Abstract
This paper presents the simulation and experimental results of a 42 V fault-tolerant six-phase induction machine (6PIM) with opened stator phases. The 6PIM has symmetrical 60 degrees displacement winding allowing fault-tolerant modes for an electric power steering (EPS) application. A voltage source inverter (VSI) in closed-loop using a vector control feeds its. The 6PIM model is derived from the stator winding distribution on a conductor-by-conductor basis and the geometrical dimensions of the different slots. A case study by simulation and experimental tests on a six-phase squirrel-cage induction machine rating 90 W, 14 V, 50 Hz, 2 poles is described and analyzed to validate the system performance in faulted modes. This paper presents also the torque ripple estimation in degraded mode using the dq0 components.

This publication has 10 references indexed in Scilit: