Comparative photon and proton dosimetry for patients with mediastinal lymphoma in the era of Monte Carlo treatment planning and variable relative biological effectiveness
Open Access
- 30 December 2019
- journal article
- research article
- Published by Springer Nature in Radiation Oncology
- Vol. 14 (1) , 1-13
Abstract
Background: Existing pencil beam analytical (PBA) algorithms for proton therapy treatment planning are not ideal for sites with heterogeneous tissue density and do not account for the spatial variations in proton relative biological effectiveness (vRBE). Using a commercially available Monte Carlo (MC) treatment planning system, we compared various dosimetric endpoints between proton PBA, proton MC, and photon treatment plans among patients with mediastinal lymphoma. Methods: Eight mediastinal lymphoma patients with both free breathing (FB) and deep inspiration breath hold (DIBH) CT simulation scans were analyzed. The original PBA plans were re-calculated with MC. New proton plans that used MC for both optimization and dose calculation with equivalent CTV/ITV coverage were also created. A vRBE model, which uses a published model for DNA double strand break (DSB) induction, was applied on MC plans to study the potential impact of vRBE on cardiac doses. Comparative photon plans were generated on the DIBH scan. Results: Re-calculation of FB PBA plans with MC demonstrated significant under coverage of the ITV V99 and V95. Target coverage was recovered by re-optimizing the PT plan with MC with minimal change to OAR doses. Compared to photons with DIBH, MC-optimized FB and DIBH proton plans had significantly lower dose to the mean lung, lung V5, breast tissue, and spinal cord for similar target coverage. Even with application of vRBE in the proton plans, the putative increase in RBE at the end of range did not decrease the dosimetric advantages of proton therapy in cardiac substructures. Conclusions: MC should be used for PT treatment planning of mediastinal lymphoma to ensure adequate coverage of target volumes. Our preliminary data suggests that MC-optimized PT plans have better sparing of the lung and breast tissue compared to photons. Also, the potential for end of range RBE effects are unlikely to be large enough to offset the dosimetric advantages of proton therapy in cardiac substructures for mediastinal targets, although these dosimetric findings require validation with late toxicity data.Keywords
This publication has 65 references indexed in Scilit:
- Dosimetric Benefits of Intensity-Modulated Radiotherapy Combined With the Deep-Inspiration Breath-Hold Technique in Patients With Mediastinal Hodgkin's LymphomaInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Calculation of the biological effects of ion beams based on the microscopic spatial damage distribution patternInternational Journal of Radiation Biology, 2011
- Development and Validation of a Heart Atlas to Study Cardiac Exposure to Radiation Following Treatment for Breast CancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2011
- Increased Risk of Stroke and Transient Ischemic Attack in 5-Year Survivors of Hodgkin LymphomaJNCI: Journal of the National Cancer Institute, 2009
- Combined Use of Monte Carlo DNA Damage Simulations and Deterministic Repair Models to Examine Putative Mechanisms of Cell KillingRadiation Research, 2008
- Biophysical calculation of cell survival probabilities using amorphous track structure models for heavy-ion irradiationPhysics in Medicine & Biology, 2007
- Collapsed cone convolution and analytical anisotropic algorithm dose calculations compared to VMC++ Monte Carlo simulations in clinical casesPhysics in Medicine & Biology, 2007
- Test of the local effect model using clinical data: tumour control probability for lung tumours after treatment with carbon ion beamsRadiation Protection Dosimetry, 2006
- A pencil beam algorithm for proton dose calculationsPhysics in Medicine & Biology, 1996
- A microdosimetric-kinetic model of cell death from exposure to ionizing radiation of any LET, with experimental and clinical applicationsInternational Journal of Radiation Biology, 1996