Abstract
S to constant-load moderate-intensity cycle ergometer exercise were determined on 15 MM, 8 McA, 21 patients with signs and/or symptoms of metabolic myopathy but a negative biopsy ("patient controls"; P-CTRL), and 22 healthy untrained controls (CTRL). Results: V˙O2 kinetics were slower in MM and in McA versus P-CTRL and CTRL, slower in McA versus MM, and not significantly different between P-CTRL and CTRL. The time constants (τ) of the monoexponential function describing the V˙O2 kinetics were (X¯ ± SE) 59.2 ± 8.5 s in MM, 87.6 ± 16.4 s in McA, 36.9 ± 3.1 s in P-CTRL, and 35.4 ± 1.9 s in CTRL. In a subgroup of the patients (eight MM and seven McA), τ of V˙O2 kinetics were negatively correlated with two variables determined in a previous study (Grassi B, Marzorati M, Lanfranconi F, et al. Impaired oxygen extraction in metabolic myopathies: detection and quantification by near-infrared spectroscopy. Muscle Nerve. 2007;35:510-20): a) a muscle oxygenation index, obtained by near-infrared spectroscopy, estimating the peak capacity of skeletal muscle fractional O2 extraction; and b) V˙O2 peak. Conclusions: In MM and McA patients, analysis of pulmonary V˙O2 kinetics during moderate-intensity exercise allows to identify and to quantify, noninvasively, the impairment of skeletal muscle oxidative metabolism. In these patients, the slower V˙O2 kinetics can be considered a marker of the impaired exercise tolerance. The present data could be useful for clinicians who need an objective, quantitative, and longitudinal evaluation of the impairment to be used in the follow-up of these patients as well as in the assessment of therapeutic interventions....

This publication has 28 references indexed in Scilit: