Significant Practice Variation in Oxygen Consumption Values in Congenital Cardiac Catheterization: Cross Sectional Survey in the United States
- 26 February 2025
- journal article
- research article
- Published by Springer Nature in Pediatric Cardiology
- Vol. 47 (2) , 660-665
Abstract
Oxygen consumption (VO2) is an essential component to calculate cardiac output using the Fick principle in the congenital cardiac catheterization laboratory (CCCL). Although VO2 can be measured, the value of VO2 is frequently assumed based on predictive equations. The objective of this study was to investigate current practice variation in measurement and estimation of VO2 in CCCL. This was a cross-sectional survey study conducted in January–February 2024. The survey (n = 114) was sent to one interventional cardiologist for each CCCL program in the United States utilizing REDCap. The responses were summarized in a descriptive fashion. Eighty eight programs completed the survey (response rate 77%). Only 13 (15%) programs measured VO2, though 67 programs (76%) thought VO2 should be measured for all cases (n = 41) and selective cases (n = 26) and 17 programs thought assumed VO2 was satisfactory. When VO2 is referred from predictive equations, most programs primarily used LaFarge (n = 64, 73%), followed by Seckeler (n = 23, 26%). For patients aged < 3 years (where LaFarge equation does not provide VO2 value) in 64 programs using LaFarge, 16 used Seckeler and the remaining 48 programs used a wide range of arbitrary VO2 values. Most CCCL thought VO2 should be measured but only 13 (15%) programs actually measured VO2 in the United States. LaFarge remains frequently used as a predictive equation. There is no standardization of clinical practice in VO2 measurement/estimation among CCCL in the United States.Keywords
This publication has 10 references indexed in Scilit:
- An Infant with High-Output Heart Failure and Pulmonary Hypertension Resulting from a Giant Cutaneous HemangiomaPediatric Cardiology, 2024
- The Estimated Fick Method Systematically Over-Estimates Cardiac Index Compared to Thermodilution in ChildrenPediatric Cardiology, 2024
- Measured Oxygen Consumption During Pediatric Cardiac Catheterization is More Accurate than Assumed Oxygen ConsumptionPediatric Cardiology, 2023
- Oxygen consumption in children and adults with congenital and acquired heart disease: the quest for better estimatesHeart, 2015
- A new predictive equation for oxygen consumption in children and adults with congenital and acquired heart diseaseHeart, 2014
- Inaccuracy of Estimated Resting Oxygen Uptake in the Clinical SettingCirculation, 2014
- Validity of the LaFarge equation for estimation of oxygen consumption in ventilated children with congenital heart disease younger than 3 years—A revisitAmerican Heart Journal, 2010
- Comparison of Calculated with Measured Oxygen Consumption in Children Undergoing Cardiac CatheterizationPediatric Cardiology, 2008
- Measured versus estimated oxygen consumption in ventilated patients with congenital heart disease: The validity of predictive equationsCritical Care Medicine, 2003
- The estimation of oxygen consumptionCardiovascular Research, 1970