Anomalous Discharge Current in Polyethylene (PE), Ethylene-Vinylacetate Copolymer (EVA) and PE-EVA Laminated Films
Authors:
- Isamu KitaniIKIsamu Kitani
- Kiyomitsu AriiKAKiyomitsu Arii
- 1 March 1985
- journal article
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 24 (3R) , 285-288
Abstract
Conduction currents and discharge currents were measured in polyethylene (PE), ethylene-vinylacetate copolymer (EVA) and PE-EVA laminated films. Anomalous discharge currents (ADC) flowing in the same direction as the charging current were observed at 10–45°C in EVA, at 25–50°C in +PE-EVA-, of which PE side was applied to positive voltage, and at 25–60°C in PE and -PE-EVA+ with evaporated silver electrodes after application of a field of strength 2.0×108V/m. The electrode material affects the ADC peak in EVA. The results are discussed on the basis of the previous reported analytic conclusions; the ADC is caused by two types of injected charges (electrons and holes).Keywords
This publication has 5 references indexed in Scilit:
- Analysis of Anomalous Discharge Current in Low-Density PolyethyleneJapanese Journal of Applied Physics, 1984
- Effect of Prestressing on the ns Range Electrical Breakdown in Polymeric Insulating FilmsJapanese Journal of Applied Physics, 1983
- Impulse Breakdown of Prestressed Polyethylene Films in the NS RangeIEEE Transactions on Electrical Insulation, 1982
- Anomalous Transient Currents in High-Density Polyethylene around 50–70°CJapanese Journal of Applied Physics, 1979
- Discharge Current from Corona Charged PolyethyleneJapanese Journal of Applied Physics, 1975