Abstract
Proteomics experiments based on Selected Reaction Monitoring (SRM, also referred to as Multiple Reaction Monitoring or MRM) are being used to target large numbers of protein candidates in complex mixtures. At present, instrument parameters are often optimized for each peptide, a time and resource intensive process. Large SRM experiments are greatly facilitated by having the ability to predict MS instrument parameters that work well with the broad diversity of peptides they target. For this reason, we investigated the impact of using simple linear equations to predict the collision energy (CE) on peptide signal intensity and compared it with the empirical optimization of the CE for each peptide and transition individually. Using optimized linear equations, the difference between predicted and empirically derived CE values was found to be an average gain of only 7.8% of total peak area. We also found that existing commonly used linear equations fall short of their potential, and should be recalculated for each charge state and when introducing new instrument platforms. We provide a fully automated pipeline for calculating these equations and individually optimizing CE of each transition on SRM instruments from Agilent, Applied Biosystems, Thermo-Scientific and Waters in the open source Skyline software tool (http://proteome.gs.washington.edu/software/skyline).Keywords
This publication has 24 references indexed in Scilit:
- Skyline: an open source document editor for creating and analyzing targeted proteomics experimentsBioinformatics, 2010
- Perspectives of targeted mass spectrometry for protein biomarker verificationCurrent Opinion in Chemical Biology, 2009
- Quantification of Cardiovascular Biomarkers in Patient Plasma by Targeted Mass Spectrometry and Stable Isotope DilutionMolecular & Cellular Proteomics, 2009
- Full Dynamic Range Proteome Analysis of S. cerevisiae by Targeted ProteomicsCell, 2009
- Correlation between y-Type Ions Observed in Ion Trap and Triple Quadrupole Mass SpectrometersJournal of Proteome Research, 2009
- Multi-site assessment of the precision and reproducibility of multiple reaction monitoring–based measurements of proteins in plasmaNature Biotechnology, 2009
- Rapid Optimization of MRM-MS Instrument Parameters by Subtle Alteration of Precursor and Product m/z TargetsJournal of Proteome Research, 2009
- Expediting the Development of Targeted SRM Assays: Using Data from Shotgun Proteomics to Automate Method DevelopmentJournal of Proteome Research, 2009
- Selected reaction monitoring for quantitative proteomics: a tutorialMolecular Systems Biology, 2008
- Quantitative, Multiplexed Assays for Low Abundance Proteins in Plasma by Targeted Mass Spectrometry and Stable Isotope DilutionMolecular & Cellular Proteomics, 2007