Ex vivo evaluation of the biomechanical effect of varying monocortical screw numbers on a plate-rod canine femoral gap model
- 1 January 2013
- journal article
- Published by Georg Thieme Verlag KG in Veterinary and Comparative Orthopaedics and Traumatology
- Vol. 26 (03) , 177-185
Abstract
Objective: To compare the biomechanical behaviour of plate-rod constructs with varying numbers of monocortical screws applied to an ex vivo canine femoral-gap ostectomy model. Sample population: Twenty Greyhound dog cadaveric femurs. Methods: Bone mineral density (BMD) was assessed with dual x-ray absorptiometry. Bones were assigned to four groups. Bones had a 12-hole 3.5 mm locking compression plate with one bicortical non-locking cortical screw in the most proximal and distal plate holes and an intramedullary Steinmann pin applied across a 20 mm mid-diaphyseal ostectomy. Additionally, one to four monocortical non-locking cortical screws were then placed (Groups 1–4 respectively) in the proximal and distal fragments. Stiffness and axial collapse were determined before and after cyclic axial loading (6000 cycles at 20%, 40%, and 60% of mean bodyweight [total: 18000 cycles]). Constructs subsequently underwent an additional 45000 cycles at 60% of bodyweight (total: 63000 cycles). Loading to failure was then performed and ultimate load and mode of failure recorded. Results: The BMD did not differ significantly between groups. Construct stiffness for group 1 was significantly less than group 4 (p = 0.008). Stiffness showed a linear increase with an increasing number of monocortical screws (p = 0.001). All constructs survived fatigue loading. Load-to-failure was not significantly different between groups. Mean load- to-failure of all groups was >1350N. Clinical relevance: Ex vivo canine large-breed femurs showed adequate stability biomechanically and gradually increasing stiffness with increasing monocortical screw numbers.Keywords
This publication has 23 references indexed in Scilit:
- Prospective Evaluation of Minimally Invasive Plate Osteosynthesis in 36 Nonarticular Tibial Fractures in Dogs and CatsVeterinary Surgery, 2011
- Veterinary Orthopedic Society 38th Annual Conference AbstractsVeterinary and Comparative Orthopaedics and Traumatology, 2011
- Minimally invasive application of a radial plate following placement of an ulnar rod in treating antebrachial fracturesVeterinary and Comparative Orthopaedics and Traumatology, 2010
- Comparison of the mechanical behaviors of semicontoured, locking plate–rod fixation and anatomically contoured, conventional plate–rod fixation applied to experimentally induced gap fractures in canine femoraAmerican Journal of Veterinary Research, 2009
- Surgical approaches for minimally invasive plate osteosynthesis in dogsVeterinary and Comparative Orthopaedics and Traumatology, 2009
- Minimally invasive plate osteosynthesis: Applications and techniques in dogs and catsVeterinary and Comparative Orthopaedics and Traumatology, 2009
- Internal plate fixation of fractures: short history and recent developmentsJournal of Orthopaedic Science, 2006
- Orthopedic clinical techniques femur fracture repairClinical Techniques in Small Animal Practice, 2004
- Minimally Invasive Plate Osteosynthesis: Does Percutaneous Plating Disrupt Femoral Blood Supply Less Than the Traditional Technique?Journal of Orthopaedic Trauma, 1999
- The role of fixator frame stiffness in the control of fracture healing. An experimental studyJournal of Biomechanics, 1993