Activation of aluminum implanted at high doses in 4H–SiC
Authors:
- 26 July 2000
- journal article
- conference paper
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 88 (4) , 1971-1977
Abstract
We report an investigation of the electrical activation of aluminum implanted at high dose in 4H–SiC. We show that at reasonably high temperature implantation and annealing conditions, one activates about 37.5% of the implanted species. Of course, the final (concentration-dependent) activation ratio differs slightly from this average value but varies only between 0.5 and 0.25 when the targeted concentration increases from to Provided a standard mobility can be maintained, this results in fairly low sheet resistance. The best (lowest) value obtained in this work is 15 mΩ cm at 700 K (95 mΩ cm at room temperature) for a 190-nm-thick layer implanted with In MESA-etched junctions with a 100 μm diameter, this resulted in a typical on-resistance of 1.5 mΩ cm2, mainly limited by the substrate and epitaxial layer.
Keywords
This publication has 24 references indexed in Scilit:
- Hall effect investigations of 4H–SiC epitaxial layers grown on semi-insulating and conducting substratesMaterials Science and Engineering: B, 1999
- Channeling implantations of Al+ into 6H silicon carbideApplied Physics Letters, 1999
- Efficient p-type doping of 6H-SiC: Flash-lamp annealing after aluminum implantationApplied Physics Letters, 1999
- Calculated Density of States and Carrier Concentration in 4H- and 6H-SiCMaterials Science Forum, 1998
- Conductivity Control of SiC by In-Situ Doping and Ion ImplantationMaterials Science Forum, 1998
- Coimplantation Effects on the Electrical Properties of Boron and Aluminium Acceptors in 4H-SiCMaterials Science Forum, 1998
- Density of states in hexagonal SiC polytypesJournal of Applied Physics, 1998
- Carbon and aluminium co-implantation for p -typedoping in 6H-SiCElectronics Letters, 1997
- Site effect on the impurity levels in,, andSiCPhysical Review B, 1980
- Photoluminescence of Radiation Defects in Ion-ImplantedSiCPhysical Review B, 1972