Lack of transferability between different immunoassays and LC-MS/MS for total 25-hydroxyvitamin D measurement and disagreement defining deficiency
- 22 November 2012
- journal article
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 73 (1) , 82-86
Abstract
Background. Over the last few years, it has become much more common to measure concentrations of vitamin D, as its deficiency has been associated with an increasing number of health problems. Recently, a number of new immunoassays for measurement of total 25-hydroxyvitamin D (25OH-D) concentration have been released but their results may not be transferable. Methods. Our main objective was to compare results from the Cobas® e411 (Roche Diagnostics), Advia Centaur® (Siemens), Architect (Abbott), IDS-iSYS (Vitro S.A.), and Liaison® (Diasorin) immunoassay systems with each other and with liquid chromatography-tandem mass spectrometry (LC-MS/MS). We obtained 184 routine serum samples, covering the whole measuring range, for these methods. Results. Kappa values above 0.8 were considered to indicate excellent agreement. With a cut-off of 50 nmol/L Architect and Cobas were the only immunoassay methods able to identify patients with deficiencies consistent with the findings of the reference method LC-MS/MS. On the other hand, using a cut-off of 37.5 nmol/L for Liaison and 75 nmol/L for IDS-iSYS, while maintaining the value of 50 nmol/L for the LC-MS/MS method, kappa values of 0.80 and 0.83 respectively were obtained. Conclusions. Choosing the best method for each laboratory is challenging due to methodological differences between them and 50 nmol/L cannot be considered as a general cut-off for defining hypovitaminosis.Keywords
This publication has 14 references indexed in Scilit:
- Patient Guide to Vitamin D DeficiencyThe Journal of Clinical Endocrinology & Metabolism, 2011
- Candidate Reference Measurement Procedures for Serum 25-Hydroxyvitamin D3 and 25-Hydroxyvitamin D2 by Using Isotope-Dilution Liquid Chromatography–Tandem Mass SpectrometryClinical Chemistry, 2011
- Progress of liquid chromatography-mass spectrometry in measurement of vitamin D metabolites and analoguesClinical Biochemistry, 2011
- Current status of clinical 25-hydroxyvitamin D measurement: An assessment of between-laboratory agreementClinica Chimica Acta, 2010
- Measurement of 25-hydroxyvitamin D in the clinical laboratory: Current procedures, performance characteristics and limitationsSteroids, 2010
- Preanalytical Stability of 25(OH)–Vitamin D3 in Human Blood or Serum at Room Temperature: Solid as a RockClinical Chemistry, 2009
- Vitamin D Deficiency in Children and Its Management: Review of Current Knowledge and RecommendationsPediatrics, 2008
- Are Clinical Laboratories Prepared for Accurate Testing of 25-Hydroxy Vitamin D?Clinical Chemistry, 2008
- Vitamin D DeficiencyThe New England journal of medicine, 2007
- Assay Variation Confounds the Diagnosis of Hypovitaminosis D: A Call for StandardizationThe Journal of Clinical Endocrinology & Metabolism, 2004