Work flow with digital intraoral radiography: A systematic review
Authors:
- 1 March 2010
- journal article
- review article
- Published by Medical Journals Sweden AB in Acta Odontologica Scandinavica
- Vol. 68 (2) , 106-114
Abstract
Objective. This systematic review evaluates the six most frequently emphasized advantages of working with digital radiography: less working time, lower radiation dose to the patient, fewer retakes and errors, wider dynamic range, easier access to patient information and easier image storage and communication. Moreover, some clinical aspects and possible disadvantages of digital imaging that were not foreseen at the beginning of the digital era, such as patient discomfort, damage to the receptor, degradation of the image, cross-contamination and viewing conditions, were assessed. Material and methods. The literature search used the PubMed database with no limits and was performed during June to August 2009. Search strategies are described in the text for each of the mentioned tasks. A hand search of task-specific journals supplemented the search strategies. Results. Time seems to be saved when switching from film to digital imaging in dental practice, a dose reduction may not be obtained, retakes and errors may be increased, the dynamic range may be wider with photostimulable storage phosphor (PSP) plates but not with sensors, the effect on patient information has not been well studied and storage and communication create new challenges with regard to handling large files and image compression. In addition, patient discomfort seems to be pronounced with sensors compared with PSP plates and film, the PSP plate may be scratched in clinical use and a two-layer barrier seems to be needed to prevent contamination of the receptor. The type of monitor may not be of major concern if the image is viewed in a room with subdued light. Conclusions. Not all of the predicted advantages with digital compared to film-based radiography hold true in daily clinical work. Of particular interest is the relationship between number of images, retakes and the dose given to the patient.Keywords
This publication has 59 references indexed in Scilit:
- Quality of individually calibrated customary printers for assessment of typical dental diagnoses on glossy paper prints: a multicenter pilot studyOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2008
- Detection of Artificial Occlusal Caries in a Phosphor Imaging Plate System with Two Types of LCD Monitors Versus Three Different FilmsJournal of Digital Imaging, 2008
- Effect of ambient light and monitor brightness and contrast settings on the detection of approximal caries in digital radiographs: anin vitrostudyDentomaxillofacial Radiology, 2008
- Factors influencing the absorbed dose in intraoral radiographyDentomaxillofacial Radiology, 2007
- Digital radiography in general dental practice: a field studyDentomaxillofacial Radiology, 2007
- A laboratory comparison of three imaging systems for image quality and radiation exposure characteristicsInternational Endodontic Journal, 2005
- Effect of delayed scanning of storage phosphor platesOral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology, 2005
- High resolution charge‐coupled device sensor vs. medium resolution photostimulable phosphor plate digital receptors for detection of root fractures in vitroDental Traumatology, 2005
- The dynamic range of digital radiographic systems: dose reduction or risk of overexposure?Dentomaxillofacial Radiology, 2004