Determination of the enantiomers of albuterol in human and canine plasma by enantioselective high-performance liquid chromatography on a teicoplanin-based chiral stationary phase
Abstract
A sensitive enantioselective high-performance chromatographic (HPLC) method was developed and validated to determine low levels of (−)-R and (+)-S-albuterol in plasma. Baseline resolution was achieved by using a teicoplanin-based chiral stationary phase with a polar organic mobile phase consisting of methanol/acetonitrile/glacial acetic acid/diethylamine, 40:60:0.3:0.2, (v/v/v/v) and a flow-rate of 1.0 ml/min. Enantioselectivity (α) equaled 1.18 and resolution (Rs) equaled 1.8. By using fluorescence detection maximized at 230 and 310 nm for excitation and emission, respectively, concentrations of each enantiomer could be measured down to 125 pg/ml from a 1-ml plasma sample. Initially, the method was applied to plasma samples from a small single-dose inhalation study of racemic albuterol in a human volunteer and, later, to in vivo samples from a canine inhalation study of the single enantiomer, (−)-R-albuterol. Results from the canine study showed that no chiral inversion of (−)-R-albuterol occurs in the dog. Chirality 10:484–491, 1998.Keywords
This publication has 28 references indexed in Scilit:
- Electrokinetic behaviour of salbutamol and its decomposition products and determination of salbutamol by micellar electrokinetic capillary chromatographyJournal of Chromatography A, 1996
- Enantioselective disposition of salbutamol in man following oral and intravenous administrationBritish Journal of Clinical Pharmacology, 1996
- A covalently bonded teicoplanin chiral stationary phase for HPLC enantioseparationsChirality, 1995
- Macrocyclic Antibiotics as a New Class of Chiral Selectors for Liquid ChromatographyAnalytical Chemistry, 1994
- Immobilized phenylboronic acids for the selective extraction of β-blocking drugs from aqueous solution and plasmaJournal of Pharmaceutical and Biomedical Analysis, 1993
- Determination of albuterol concentrations in human plasma using solid-phase extraction and high-performance liquid chromatography with fluorescence detectionJournal of Pharmaceutical and Biomedical Analysis, 1990
- Salbutamol in the 1980sDrugs, 1989
- Routine determination of urinary free catecholamines by high-performance liquid chromatography with electrochemical detectionJournal of Chromatography B: Biomedical Sciences and Applications, 1988
- Quantitative analysis of albuterol in human plasma by combined gas chromatography chemical ionization mass spectrometryJournal of Mass Spectrometry, 1983
- Simultaneous determination of terbutaline and salbutamol in plasma by selected ion monitoringJournal of Mass Spectrometry, 1982