Learned high resolution energy‐integrating detector CT angiography: Harnessing the power of ultra‐high‐resolution photon counting detector CT
Authors:
- 8 May 2025
- journal article
- Published by Wiley in Medical Physics
- Vol. 52 (7) , e17874
Abstract
Background: Coronary computed tomography angiography (cCTA) is a widely used noninvasive diagnostic exam to assess patients for coronary artery disease (CAD). However, the spatial resolution of most CT scanners is limited due to the use of energy‐integrating detectors (EIDs). Purpose: To develop a convolutional neural network ( I mproved LUMEN visualization through A rtificial super‐resolu T ion imag E s (ILUMENATE)) informed by photon‐counting‐detector (PCD)‐CT to improve EID‐CT image resolution and determine its impact on cCTA. Materials and methods: With IRB approval, 30 patients undergoing clinically indicated cCTA were scanned with EID‐CT (SOMATOM Force, Siemens Healthineers, Forchheim, Germany) and subsequently with ultra‐high‐resolution (UHR) PCD‐CT (NAEOTOM Alpha, Siemens Healthineers) on the same day. ILUMENATE was trained on eight patient PCD‐CT datasets (67,890 patch pairs with 90% for training (61,101), 10% reserved for validation (6,789)) and applied to 22 unseen EID‐CT cases. Spatial resolution was evaluated using line profiles and percent diameter stenosis quantified with a severity score assigned. Two experienced radiologists, blinded to image type, selected preferred series and scored images for overall quality, sharpness, and noise comparing original EID‐CT and ILUMENATE output. Results: Visual assessment and line profiles showed substantial resolution improvement with ILUMENATE. Percent diameter stenosis was significantly reduced (mean ± standard deviation: 4.42% ± 4.82%) using ILUMENATE ( p < 0.001) with nine lesions shifting down in severity score. Readers preferred ILUMENATE images in 22/22 cases and scored ILUMENATE superiorly for overall quality, sharpness, and noise ( p < 0.05). Conclusions: ILUMENATE enhanced image resolution, resulting in improved overall image quality, reduced calcium blooming artifacts, and improved lumen visibility in cCTA exams performed using EID‐CT. This could potentially allow for improved accessibility to UHR image quality, allowing for more accurate assessment of CAD.Keywords
Funding Information
- National Institutes of Health (R01 EB028590)
This publication has 27 references indexed in Scilit:
- Ultra-high-resolution photon-counting detector CT in evaluating coronary stent patency: a comparison to invasive coronary angiographyEuropean Radiology, 2024
- Coronary artery stenosis quantification in patients with dense calcifications using ultra-high-resolution photon-counting-detector computed tomographyJournal of Cardiovascular Computed Tomography, 2023
- Improving image quality with super-resolution deep-learning-based reconstruction in coronary CT angiographyEuropean Radiology, 2023
- 2021 AHA/ACC/ASE/CHEST/SAEM/SCCT/SCMR Guideline for the Evaluation and Diagnosis of Chest PainJACC, 2021
- A review on coronary artery disease, its risk factors, and therapeuticsJournal of Cellular Physiology, 2019
- Cardiac Imaging in the Diagnosis of Coronary Artery DiseaseCurrent Problems in Cardiology, 2017
- Negative predictive value of stress myocardial perfusion imaging and coronary computed tomography angiography: A meta-analysisJournal of Nuclear Cardiology, 2017
- U-Net: Convolutional Networks for Biomedical Image Segmentation2015
- Learning a Deep Convolutional Network for Image Super-Resolution2014
- Image quality and artifacts in coronary CT angiography with dual-source CT: Initial clinical experienceJournal of Cardiovascular Computed Tomography, 2008