Comparison of Two Different Approaches toward Model Transferability in NIR Spectroscopy
Authors:
- 1 January 1998
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 52 (1) , 7-16
Abstract
Recently, efficient methods have become available to transfer a multivariate calibration model from one instrument to another. Two categories can be distinguished: improvement of the robustness of the calibration model by, for example, a proper data preprocessing; and adaptation of the calibration model by, for example, (piecewise) direct standardization. In direct standardization, a subset from the calibration set should be measured on both instruments. Usually, however, the calibration samples cannot be measured on both instruments. When data preprocessing is applied to the transfer of multivariate calibration models, there is no need for remeasurement of a subset on both instruments. In this paper, both categories are compared for the determination of the component concentrations in a ternary mixture of methanol, ethanol, and 1-propanol using NIR spectroscopy. The calibration models obtained on one instrument are transferred to other NIR instruments. It has been found that the results of proper data preprocessing are comparable with the results obtained by direct standardization when the models are transferred over three NIR instruments.Keywords
This publication has 19 references indexed in Scilit:
- Mathematical Alignment of Wavelength-Shifted Optical Spectra for Qualitative and Quantitative AnalysisApplied Spectroscopy, 1996
- Comparison of semirobust and robust partial least squares proceduresChemometrics and Intelligent Laboratory Systems, 1995
- Process Analytical ChemistryAnalytical Chemistry, 1995
- Robust principal components regression as a detection tool for outliersChemometrics and Intelligent Laboratory Systems, 1995
- Multivariate calibration standardizationChemometrics and Intelligent Laboratory Systems, 1994
- Interactive variable selection (IVS) for PLS. Part 1: Theory and algorithmsJournal of Chemometrics, 1994
- Infrared SpectroscopyAnalytical Chemistry, 1994
- Multivariate instrument standardizationAnalytical Chemistry, 1991
- Achieving transferable multivariate spectral calibration models: demonstration with infrared spectra of thin-film dielectrics on siliconAnalytical Chemistry, 1991
- Standard Normal Variate Transformation and De-Trending of Near-Infrared Diffuse Reflectance SpectraApplied Spectroscopy, 1989