Hemodynamic factors of aortic dilatation after thoracic endovascular aortic repair for type-B aortic dissection
Open Access
- 22 April 2026
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 14, 1780047
Abstract
Objective: We aimed to investigate the hemodynamic factors associated with aortic dilatation following thoracic endovascular aortic repair (TEVAR) for type-B aortic dissection (TBAD). Methods: This retrospective study enrolled patients who developed aortic dilatation following TEVAR for TBAD, patients who did not develop aortic dilatation following TEVAR for TBAD, and healthy control subjects. Computed tomography angiography (CTA) images for the dilatation group were acquired at three time points: pre-TEVAR (Group A), 1-week post-TEVAR (Group B), and the most recent follow-up (Group C). For the non-dilatation group, CTA images were acquired pre-TEVAR (Group D) and 1 week post-TEVAR (Group E). The control group underwent a single CTA examination (Group F). Three-dimensional (3D) models were reconstructed from CTA images, and computational fluid dynamics (CFD) simulations were performed. The oscillatory shear index (OSI) at the ostia of the major arterial branches was defined as the primary CFD endpoint. Results: In the dilatation group, the pressures at the ostia of the brachiocephalic trunk, left common carotid artery, left subclavian artery, celiac trunk, superior mesenteric artery, bilateral renal arteries, inferior mesenteric artery, and bilateral common iliac arteries were lower in Group B than in Groups A and C. In the non-dilatation group, the pressures at the ostia of the brachiocephalic trunk, left common carotid artery, left subclavian artery, celiac trunk, superior mesenteric artery, left renal artery, inferior mesenteric artery, and right common iliac artery were higher in Group E than in Group D. The false lumen in Group B exhibited a larger region of high OSI compared with that in Group E. Conclusion: Elevated OSI in the false lumen is associated with a greater tendency toward aortic dilatation following TEVAR for TBAD. Patients with reduced true lumen pressure in the early post-TEVAR period show a corresponding trend toward subsequent aortic dilatation.Keywords
This publication has 35 references indexed in Scilit:
- European Society for Vascular Surgery (ESVS) 2026 Clinical Practice Guidelines on the Management of Descending Thoracic and Thoraco-Abdominal Aortic Diseases – Editor's ChoiceEuropean Journal of Vascular and Endovascular Surgery, 2025
- False lumen hemodynamics and partial thrombosis in chronic aortic dissection of the descending aortaEuropean Radiology, 2024
- A hemodynamic analysis of fenestrated physician-modified endograft repair for complicated aortic dissections involving the visceral arteriesComputer Methods and Programs in Biomedicine, 2023
- Ascending aortic volume: A feasible indicator for ascending aortic aneurysm elective surgery?Acta Biomaterialia, 2023
- Influence of aortic aneurysm on the local distribution of NO and O2 using image-based computational fluid dynamicsComputers in Biology and Medicine, 2023
- Morphological parameters affecting false lumen thrombosis following type B aortic dissection: a systematic study based on simulations of idealized modelsBiomechanics and Modeling in Mechanobiology, 2023
- Updates in aortic wall pathologySurgery Today, 2021
- Coupled Morphological–Hemodynamic Computational Analysis of Type B Aortic Dissection: A Longitudinal StudyAnnals of Biomedical Engineering, 2018
- Elevated Wall Shear Stress in Aortic Type B Dissection May Relate to Retrograde Aortic Type A Dissection: A Computational Fluid Dynamics Pilot StudyEuropean Journal of Vascular and Endovascular Surgery, 2017
- Computational Study of Haemodynamic Effects of Entry- and Exit-Tear Coverage in a DeBakey Type III Aortic Dissection: Technical ReportEuropean Journal of Vascular and Endovascular Surgery, 2011