Highly Sensitive and Flexible Copper Oxide/Graphene Non‐Enzymatic Glucose Sensor by Laser Direct Writing
Authors:
Open Access
- 8 February 2023
- journal article
- research article
- Published by Wiley in Advanced Sensor Research
- Vol. 2 (6)
Abstract
Accurate and convenient detection of human blood glucose levels is an effective method for early diagnosis of diabetes and prevention of complications. The flexible and wearable electrochemical glucose sensor with low cost, fast responsiveness, good stability, reliability, and high sensitivity has attracted much attention in monitoring glucose concentration. The preparation of a conductive layer with catalytic activity on a flexible substrate is the key to making a wearable glucose sensor. Here, graphene composite materials sintered with copper oxide (CuO) nanoparticles are successfully prepared on a polyimide film by laser direct writing method and fabricated a flexible non‐enzymatic glucose sensor using laser‐engraved graphene (LEG) as a conductive electrode. The CuO/LEG sensor exhibits a high sensitivity of 619.43 μA mm−1 cm−2 in 0–3 mm glucose and 462.96 μA mm−1 cm−2 in 0–8 mm glucose. In addition, the CuO/LEG sensor shows good reproducibility, high anti‐interference capability, and long‐term stability. It also presents good bending stability, which can maintain 82.40% initial current after 100 times bending. Moreover, the CuO/LEG sensor has an obvious step‐ampere response in the detection of sweat samples, indicating the great potential of wearable sweat sensors.Keywords
Funding Information
- National Key Research and Development Program of China (2020YFB2008500)
- National Natural Science Foundation of China (51835003, 52205154, 61804054)
This publication has 58 references indexed in Scilit:
- Pd nanocube as non-enzymatic glucose sensorSensors and Actuators B: Chemical, 2015
- Preparation of reduced graphene oxide/Cu nanoparticle composites through electrophoretic deposition: application for nonenzymatic glucose sensingRSC Advances, 2015
- Enhanced non-enzymatic glucose sensing based on copper nanoparticles decorated nitrogen-doped grapheneBiosensors and Bioelectronics, 2014
- Electrochemical Deposition of Mesoporous Pt–Au Alloy Films in Aqueous Surfactant Solutions: Towards a Highly Sensitive Amperometric Glucose SensorChemistry – A European Journal, 2013
- Recent advances in electrochemical glucose biosensors: a reviewRSC Advances, 2012
- Application of a Cu–Co alloy dendrite on glucose and hydrogen peroxide sensorsElectrochimica Acta, 2012
- A novel non-enzymatic glucose sensor based on Cu nanoparticle modified graphene sheets electrodeAnalytica Chimica Acta, 2012
- Fast growth of graphene patterns by laser direct writingApplied Physics Letters, 2011
- Immobilization of glucose oxidase and platinum on mesoporous silica nanoparticles for the fabrication of glucose biosensorElectrochimica Acta, 2011
- Self-assembled microstructure of carbon nanotubes for enzymeless glucose sensorSensors and Actuators B: Chemical, 2009