Comparison of ultrashort echo time sequences for MRI of an ancient mummified human hand
- 7 March 2015
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 75 (2) , 701-708
Abstract
Purpose To compare the three different short‐echo time (TE) pulse sequences ultrashort echo time (UTE), point‐wise encoding time reduction with radial acquisition (PETRA), and single point imaging (SPI) for MRI of ancient remains. Methods MRI of mummies is challenging due to the extremely low water content and the very short transverse relaxation times T2*. To overcome the signal loss associated with the short T2*, three pulse sequences with very short TEs were compared. MR images of an ancient mummified human hand were acquired at field strengths of 1.5 Tesla (T) and 3T using home‐made solenoid Tx/Rx radiofrequency (RF) coils. Results In all MR images, tissues could be differentiated and anatomical structures such as bones and tendons were clearly identified. Skin with embalming resin was hyperintense in MRI, whereas it appeared iso‐intense in computed tomography. PETRA has the highest signal to noise ratio. With UTE, short scan times and a homogeneous RF excitation can be achieved, and blurring is less pronounced than with PETRA. SPI shows no blurring artifacts; however, it requires long scan times. Conclusion This work provided an initial analysis for the optimization of imaging protocols for paleoradiology studies with MRI, and, ultimately, for MRI of tissue with extremely short T2*. Magn Reson Med, 2015.Keywords
This publication has 41 references indexed in Scilit:
- Ultrashort echo time (UTE) imaging with bi-component analysis: Bound and free water evaluation of bovine cortical bone subject to sequential dryingBone, 2012
- Quantifying cortical bone water in vivo by three‐dimensional ultra‐short echo‐time MRINMR in Biomedicine, 2011
- Characterization of 1H NMR signal in human cortical bone for magnetic resonance imagingMagnetic Resonance in Medicine, 2010
- Magnetic resonance imaging performed on a hydrated mummy of medieval KoreaJournal of Anatomy, 2010
- Cortical Bone Water: In Vivo Quantification with Ultrashort Echo-Time MR ImagingRadiology, 2008
- Measurements of mobile and bound water by nuclear magnetic resonance correlate with mechanical properties of boneBone, 2008
- Non-invasive spatial tissue discrimination in ancient mummies and bones in situ by portable nuclear magnetic resonanceJournal of Cultural Heritage, 2007
- Saturated double‐angle method for rapid B1+ mappingMagnetic Resonance in Medicine, 2006
- High resolution NMR imaging in solidsPhysica B+C, 1985
- The Use of Natron in MummificationThe Journal of Egyptian Archaeology, 1932