Comparison of Breath- and Blood-Alcohol Concentrations in a Controlled Drinking Study
- 14 July 2021
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of Analytical Toxicology
- Vol. 46 (6) , 683-688
Abstract
In this work, 114 volunteers were dosed with 80-proof liquor to produce peak blood-alcohol concentration (BAC) or breath-alcohol concentration (BrAC) of 0.040–0.080 g/100 mL blood or g/210 L breath. This was followed by a 30 minute deprivation period before simultaneous blood and breath samples were collected and the alcohol concentration quantified. BAC was determined by gas chromatography with flame ionization detection and BrAC by a dual-sensor Intox EC/IR II instrument. Paired Student t-tests showed that differences between paired blood- and breath-alcohol results differed significantly. Results from these two measurement methods are highly correlated and, on average, measured BAC was 11.3% greater than BrAC. There were 10 instances of BrAC being greater than the corresponding BAC, and the average difference between these two values was 0.0059 g/100 mL. Agreement plots of coupled BAC and BrAC revealed a mean bias of 0.00754 g/100 mL and 95% limits of agreement (LOA) at −0.00705 and 0.0221 g/100 mL. Once BrAC values were truncated to the hundredths place as required by Wisconsin state statute, only three participants had greater BrAC than corresponding BAC, with an average difference between these values of 0.008 g/100 mL. Agreement plots with truncated BrAC values gave a mean bias of 0.0120 g/100 mL and 95% LOA at −0.00344 and 0.0275 g/100 mL. Data showed that typically, blood samples had greater alcohol concentrations than corresponding breath values. Differences were exacerbated by Wisconsin’s statutory requirement that reported breath alcohol measurements be truncated to the hundredths place, whereas blood has no corresponding mandate.Keywords
This publication has 16 references indexed in Scilit:
- Comparison of venous blood alcohol concentrations and breath alcohol concentrations measured with Draeger Alcotest 9510 DE EvidentialForensic Science International, 2016
- Blood Alcohol and Breath Alcohol Comparisons using the Intox EC/IR IICanadian Society of Forensic Science Journal, 2012
- Concentration dependency of the BAC/BrAC (blood alcohol concentration/breath alcohol concentration) conversion factor during the linear elimination phaseInternational journal of legal medicine, 2003
- Comparison of ethanol concentrations in venous blood and end-expired breath during a controlled drinking studyForensic Science International, 2003
- SPECIAL ARTICLE COMPARING METHODS OF MEASUREMENTClinical and Experimental Pharmacology and Physiology, 1997
- Variability of the Blood/Breath Alcohol Ratio in Drinking DriversJournal of Forensic Sciences, 1996
- Pharmacokinetics of ethanol in saliva: comparison with blood and breath alcohol profiles, subjective feelings of intoxication, and diminished performanceClinical Chemistry, 1993
- Breathalyzer® Accuracy in Actual Law Enforcement Practice: A Comparison of Blood- and Breath-Alcohol Results in Wisconsin DriversJournal of Forensic Sciences, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Use and Interpretation of Common Statistical Tests in Method-Comparison StudiesClinical Chemistry, 1973