Ultrasound-to-computer-tomography registration for image-guided laparoscopic liver surgery
Authors:
- R. GallowayRGR. Galloway
- A. HerlineAHA. Herline
- 10 January 2005
- journal article
- Published by Springer Nature in Surgical Endoscopy
- Vol. 19 (3) , 424-429
Abstract
The application of image-guided surgery (IGS) to laparoscopic liver resection and ablation is currently limited, but it would assist in intraoperative decision making regarding oncologic margins, ablation probe placement, and ablation tracking. Eight spherical surface targets on a liver phantom were imaged with an optically tracked laparoscopic ultrasound (US) probe. Ten US images of each target were registered to computer tomography (CT) images of the phantoms and then mapped to the CT scans. Accuracy of the registration was assessed by comparing the distance between the predicted target location and the position obtained directly from CT. The average localization error was 5.3 mm. The errors resulted primarily from inaccurate US probe tracking but were otherwise insensitive to the variability that arises from manually identifying targets in US and CT images. The results obtained for US-to-CT registration in a phantom model suggest that further investigations into its clinical use are warranted and that other IGS technologies could be applied to laparoscopic liver surgery as well.Keywords
This publication has 18 references indexed in Scilit:
- Laparoscopic Versus Open Left Lateral Hepatic Lobectomy: A Case-Control StudyJournal of the American College of Surgeons, 2003
- Three-dimensional image registration of phantom vertebrae for image-guided surgery: A preliminary studyComputer Aided Surgery, 2002
- Laparoscopic radiofrequency ablation of unresectable hepatic malignanciesSurgical Endoscopy, 2001
- Registration Methodology2001
- Laparoscopic Liver Resections: A Feasibility Study in 30 PatientsAnnals of Surgery, 2000
- Registration of physical space to laparoscopic image space for use in minimally invasive hepatic surgeryIEEE Transactions on Medical Imaging, 2000
- Laparoscopy extends the indications for liver resection in patients with cirrhosisBritish Journal of Surgery, 1999
- Predicting error in rigid-body point-based registrationIEEE Transactions on Medical Imaging, 1998
- Interactive image-guided neurosurgeryIEEE Transactions on Biomedical Engineering, 1992
- Least-squares estimation of transformation parameters between two point patternsIEEE Transactions on Pattern Analysis and Machine Intelligence, 1991