Abstract
Aim: N8‐GP (turoctocog alfa pegol) is a glycoPEGylated, extended half‐life human recombinant factor VIII (FVIII) shown to be an efficacious treatment for patients with haemophilia A. Accurate monitoring of replacement therapy helps ensure proper dosing, leading to better patient care. The objective of this field study was to evaluate the accuracy and intra‐ and inter‐laboratory variabilities of N8‐GP and rAHF (Advate®) FVIII activity (FVIII:C) measurements in clinical laboratories using their routine methods and reagents.Methods: Laboratories measured plasma samples spiked with 0.03, 0.2, 0.6 and 0.9 IU/mL N8‐GP or rAHF. Samples were blinded, and laboratories were instructed to perform evaluations using their routine FVIII activity assays and calibrators.Results: Of the 67 participating laboratories from 25 countries, 60 used a one‐stage assay, 36 used a chromogenic assay, and 29 used both one‐stage and chromogenic assays. Participating laboratories used nine different activated partial thromboplastin time (aPTT) reagents, the most common being SynthASil® and Actin® FS. Most aPTT reagents recovered N8‐GP close to target. Three silica‐based aPTT reagents (APTT‐SP, TriniCLOT™ and STA® PTT‐Automate) underestimated N8‐GP, recovering 40%‐83% of target concentration. For chromogenic assays, N8‐GP and rAHF recoveries were comparable at all concentrations, with overall mean recoveries for both products close to 130%. Assay variability was similar for both assay types and both products; inter‐laboratory variability was greater than intra‐laboratory variability and highest at 0.03 IU/mL.Conclusions: Most clinical laboratories accurately measured N8‐GP and rAHF when using their in‐house one‐stage or chromogenic FVIII:C assays. However, three silica‐based aPTT reagents underestimated N8‐GP recovery.Keywords
Funding Information
- Novo Nordisk
This publication has 22 references indexed in Scilit:
- Factor VIII activity of BAY 94‐9027 is accurately measured with most commonly used assays: Results from an international laboratory studyHaemophilia, 2018
- Discrepancies between the one‐stage clotting assay and the chromogenic assay in haemophilia BHaemophilia, 2017
- Clinical evaluation of glycoPEGylated recombinant FVIII: Efficacy and safety in severe haemophilia AThrombosis and Haemostasis, 2017
- Assay discrepancy in mild haemophilia AEuropean Journal of Haematology, 2014
- Evaluation of the activated partial thromboplastin time assay for clinical monitoring of PEGylated recombinant factor VIII (BAY 94‐9027) for haemophilia AHaemophilia, 2014
- Comparative field study evaluating the activity of recombinant factor VIII Fc fusion protein in plasma samples at clinical haemostasis laboratoriesHaemophilia, 2013
- A novel B-domain O-glycoPEGylated FVIII (N8-GP) demonstrates full efficacy and prolonged effect in hemophilic mice modelsBlood, 2013
- Recommendations on the potency labelling of factor VIII and factor IX concentratesJournal of Thrombosis and Haemostasis, 2013
- Standards and monitoring treatmentHaemophilia, 2012