Carbon nanohorn modified platinum electrodes for improved immobilisation of enzyme in the design of glutamate biosensors
- 25 July 2019
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 144 (17) , 5299-5307
Abstract
Electrochemical enzymatic biosensors are the subject of research due to their potential for in vivo monitoring of glutamate, which is a key neurotransmitter whose concentration is related to healthy brain function. This study reports the use of biocompatible oxidised carbon nanohorns (o-CNH) with a high surface area, to enhance the immobilization of glutamate oxidase (GluOx) for improved biosensor performance. Two families of biosensors were designed to interact with the anionic GluOx. Family-1 consists of covalently functionalised o-CNH possessing hydrazide (HYZ) and amine (PEG-NH2) terminated surfaces and Family-2 comprised non-covalently functionalised o-CNH with different loadings of polyethyleneimine (PEI) to form a cationic hybrid. Amperometric detection of H2O2 formed by enzymatic oxidation of glutamate revealed a good performance from all designs with the most improved performance by the PEI hybrid systems. The best response was from a o-CNH : PEI ratio of 1 : 10 mg mL−1, which yielded a glutamate calibration plateau, JMAX, of 55 ± 9 μA cm−2 and sensitivity of 111 ± 34 μA mM−1 cm−2. The low KM of 0.31 ± 0.05 mM indicated the retention of the enzyme function, and a limit of detection of 0.02 ± 0.004 μM and a response time of 0.88 ± 0.13 s was determined. The results demonstrate the high sensitivity of these biosensors and their potential for future use for the detection of glutamate in vivo.Keywords
Funding Information
- Irish Research Council (GOIPG/2016/805)
- University College Dublin
This publication has 42 references indexed in Scilit:
- Highly selective and stable microdisc biosensors for l-glutamate monitoringSensors and Actuators B: Chemical, 2013
- Immobilization Method to Preserve Enzyme Specificity in Biosensors: Consequences for Brain Glutamate DetectionAnalytical Chemistry, 2013
- Nanomolar Detection of Glutamate at a Biosensor Based on Screen‐Printed Electrodes Modified with Carbon NanotubesElectroanalysis, 2011
- Graphene for electrochemical sensing and biosensingTrAC Trends in Analytical Chemistry, 2010
- Graphene Based Electrochemical Sensors and Biosensors: A ReviewElectroanalysis, 2010
- Recent trends in microdialysis sampling integrated with conventional and microanalytical systems for monitoring biological events: A reviewAnalytica Chimica Acta, 2009
- Microsensors for in vivo Measurement of Glutamate in Brain TissueSensors, 2008
- Photoinduced antiviral carbon nanohornsNanotechnology, 2008
- Solubilization of Single-Wall Carbon Nanohorns Using a PEG−Doxorubicin ConjugateMolecular Pharmaceutics, 2006
- Criterion for Hill equation validity for description of biosensor calibration curvesAnalytica Chimica Acta, 2001