The air‐Q ® intubating laryngeal airway vs the LMA‐ProSeal TM : a prospective, randomised trial of airway seal pressure*
Open Access
- 22 August 2011
- journal article
- research article
- Published by Wiley in Anaesthesia
- Vol. 66 (12) , 1093-1100
Abstract
Summary: We performed a prospective, open‐label, randomised controlled trial comparing the air‐Q ® against the LMA‐ProSeal™ in adults undergoing general anaesthesia. One hundred subjects (American Society of Anesthesiologists physical status 1–3) presenting for elective, outpatient surgery were randomly assigned to 52 air‐Q ® and 48 ProSeal devices. The primary study endpoint was airway seal pressure. Oropharyngolaryngeal morbidity was assessed secondarily. Mean (SD) airway seal pressures for the air‐Q ® and ProSeal were 30 (7) cmH 2 O and 30 (6) cmH 2 O, respectively (p = 0.47). Postoperative sore throat was more common with the air‐Q ® (46% vs 38%, p = 0.03) as was pain on swallowing (30% vs 5%, p = 0.01). In conclusion, the air‐Q ® performs well as a primary airway during the maintenance of general anaesthesia with an airway seal pressure similar to that of the ProSeal, but with a higher incidence of postoperative oropharyngolaryngeal complaints. You can respond to this article at http://www.anaesthesiacorrespondence.comKeywords
This publication has 34 references indexed in Scilit:
- CobraPLUS and Cookgas air-Q versus Fastrach for blind endotracheal intubation: a randomised controlled trialEuropean Journal of Anaesthesiology, 2011
- Use of Manometry for Laryngeal Mask Airway Reduces Postoperative Pharyngolaryngeal Adverse EventsAnesthesiology, 2010
- Fibreoptic intubation through Cookgas intubating laryngeal airway in two childrenAnaesthesia, 2009
- A comparison of the disposable Ambu ® AuraOnce ™ Laryngeal Mask with the reusable LMA Classic ™ laryngeal mask airway*Anaesthesia, 2007
- Comparison of LMA Unique, Ambu laryngeal mask and Soft Seal laryngeal mask during routine surgical proceduresEuropean Journal of Anaesthesiology, 2007
- A comparison of the Soft Seal ™ disposable and the Classic re‐usable laryngeal mask airway*Anaesthesia, 2006
- A Comparison of the Laryngeal Mask Airway and Cuffed Oropharyngeal Airway in Anesthetized Adult PatientsAnesthesia & Analgesia, 1998
- Selection of the Proper Size of Laryngeal Mask Airway in AdultsAnesthesia & Analgesia, 1996
- The distance between the grille of the laryngeal mask airway and the vocal cordsAnaesthesia, 1993
- Statistics and ethics in medical research: III How large a sample?BMJ, 1980