On-line solid phase extraction-hydride generation atomic fluorescence spectrometric determination of trace arsenic in high purity antimony(iii) oxide
- 18 November 2009
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 25 (2) , 206-209
Abstract
The determination of As(III) in high purity Sb2O3 was taken as example to illustrate a high selective solid phase extraction (SPE) with non-polar resins as the sorbent. The extraction was based on the fact that in concentrated HCl solutions, As(III) forming molecular covalent AsCl3 could be attracted by the hydrophobic phase of the resins, whereas the matrix Sb existing only as the ionic Sb–Cl complex could not be adsorbed. The SPE column was made from the Amberlite XAD-16 resin and was on-line coupled with hydride generation atomic fluorescence spectrometer for As(III) detection. Under the optimized conditions, the detection limit (3σ) of 0.26 μg g−1, the RSD (n = 6) of 6.2% for 50 μg L−1 of As(III) and a linear calibration curve from 2 μg L−1 to 200 μg L−1 with R = 0.9998 were obtained. The recoveries for 10 μg L−1 of As(III) spiked in 1 g L−1 of Sb(III) solution was in the range of 97–102%. The method was applied to the determination of trace As(III) in two highly pure Sb2O3 samples.Keywords
This publication has 11 references indexed in Scilit:
- Atomic absorption spectrometric determination of Cd(II), Mn(II), Ni(II), Pb(II) and Zn(II) ions in water, fertilizer and tea samples after preconcentration on Amberlite XAD-1180 resin loaded with l-(2-pyridylazo)-2-naphtholJournal of Analytical Chemistry, 2009
- Solid phase chelating extraction and separation of inorganic antimony species in pharmaceutical and water samples for graphite furnace atomic absorption spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 2008
- Selective detection of trace lead in lead-free solder alloy by flow injection on-line solid-phase extraction using a macrocycle immobilized silica gel as sorbent coupled with hydride generation atomic fluorescence spectrometryJournal of Analytical Atomic Spectrometry, 2007
- Separation of Gold, Palladium and Platinum from Metallurgical Samples Using an Amberlite XAD-7 Resin Column Prior to Their Atomic Absorption Spectrometric DeterminationsAnalytical Sciences, 2003
- Thiosalicylic acid-immobilized Amberlite XAD-2: metal sorption behaviour and applications in estimation of metal ions by flame atomic absorption spectrometryThe Analyst, 2000
- Electrothermal vaporization-ICP-MS for the determination of metals in micro amounts of high-purity non-metals (P, As, Sb, S, Se, Te, I)Analytical and Bioanalytical Chemistry, 1998
- Determination of some trace elements in high-purity aluminium, zinc and commercial steel by AAS after preconcentration on amberlite XAD-1180 resinMicrochimica Acta, 1997
- Speciation of chromium using reversed phase-high performance liquid chromatography coupled to different spectrometric detection methodsSpectrochimica Acta Part B: Atomic Spectroscopy, 1997
- Determination of Gold in Geological Samples and Anode Slimes by Atomic Absorption Spectrometry After Preconcentration Wth Amberlite XAD-16 ResinThe Analyst, 1997
- Determination of Copper, Cadmium, Lead and Bismuth in High-Purity Zinc Metal Samples by Atomic Absorption Spectrometry after Preconcentration Using Amberlite XAD-1180 Resin.Analytical Sciences, 1994