The role of the depth of resection of the distal tibia on biomechanical performance of the tibial component for TAR: A finite element analysis with three implant designs
Authors:
- JyotiJYJyoti
- Rajesh GhoshRGRajesh Ghosh
- 7 August 2023
- journal article
- research article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 119 (1) , 104034
Abstract
The depth of resection of the tibia bone in total ankle replacement (TAR) may influence implant-bone micromotion and stress shielding. High implant-bone micromotion and stress-shielding lead to aseptic loosening of the tibial component for TAR. The aim was to improve the outcomes of the different designs of TAR (STAR, Mobility, and Salto) with the variation of the depth of resection of the distal tibia bone. Finite element (FE) models of the implanted tibia with the depth of resection varying from 6 mm to 16 mm and of the intact tibia was prepared. The value of micromotion increased as the depth of resection increased. The micromotion increased in the proximal anterior-posterior portion of the pegs for STAR, the posterior part of the stem for Mobility, and the proximal lateral portion of the keel for Salto with the increase in the depth of resection. Whereas, the stresses (von Mises) decreased in some regions and increased in some regions depending upon the implant design. But overall stresses decreased in the tibia bone. Furthermore, the mean stress shielding increased in all the designs as the depth of resection increased. This in silico study indicated that the depth of resection should be given more importance during TAR surgery. The ideal depth of resection should be minimum i.e., 6 mm based on this FE study.Keywords
Funding Information
- Indian Institute of Technology Mandi
This publication has 38 references indexed in Scilit:
- Clinical and Radiographic Outcomes of the Mobility Total Ankle Arthroplasty SystemFoot & Ankle International, 2013
- Longitudinal migration and inducible displacement of the Mobility Total Ankle SystemActa Orthopaedica, 2012
- Computed-tomography-based finite-element models of long bones can accurately capture strain response to bending and torsionJournal of Biomechanics, 2011
- History and evolution in total ankle arthroplastyBritish Medical Bulletin, 2008
- Comparison of an inhomogeneous orthotropic and isotropic material models used for FE analysesMedical Engineering & Physics, 2008
- Aseptic loosening, not only a question of wear: A review of different theoriesActa Orthopaedica, 2006
- Malleolar Fracture after Total Ankle ArthroplastyClinical Orthopaedics and Related Research, 2004
- Hydroxyapatite ceramic coating for bone implant fixationActa Orthopaedica, 1993
- The effect of specimen geometry on the mechanical behaviour of trabecular bone specimensJournal of Biomechanics, 1992
- The prediction of muscular load sharing and joint forces in the lower extremities during walkingJournal of Biomechanics, 1975