A Variable Column Length Strategy To Expedite Method Development
- 30 December 2010
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (3) , 966-975
Abstract
A variable length method development (or VL-MD)strategy, exploiting the potential of an automatic column coupling system, is proposed and has been applied to a number of different pharmaceutical and environmental samples with a varying degree of complexity. The proposed strategy consistently produced separation methods that had at least an equally good critical pair resolution and an equally short run time to those of methods produced using commercially available MD assistance software. In some cases, the VL-MD strategy allowed the MD time to be drastically shortened from >30 h to an overnight run of only 12 h. The developed strategy has the potential to become fully automated provided that reliable chromatogram read-out software becomes available. The advantage of combining different stationary phase types to improve the available selectivity and the integration into the general VL-MD strategy was also demonstrated.Keywords
This publication has 25 references indexed in Scilit:
- Determination of fluoroquinolone antibiotics in wastewater using ultra high‐performance liquid chromatography with mass spectrometry and fluorescence detectionJournal of Separation Science, 2010
- Lactic acid quantitation in hand dishwashing liquid using an HILIC‐UV methodologyJournal of Separation Science, 2010
- Stationary-Phase Optimized Selectivity Liquid Chromatography: Development of a Linear Gradient Prediction AlgorithmAnalytical Chemistry, 2010
- Efficient method development strategy for challenging separation of pharmaceutical molecules using advanced chromatographic technologiesJournal of Chromatography A, 2007
- Development and validation of a stability-indicating reversed-phase high performance liquid chromatography method for NPC 1161C, a novel 8-aminoquinoline anti-malarial drugJournal of Chromatography A, 2006
- Computer-assisted optimization in the development of a high-performance liquid chromatographic method for the analysis of kava pyrones in Piper methysticum preparationsJournal of Chromatography A, 2002
- Separation of Barbiturates and Phenylthiohydantoin Amino Acids Using the Thermally Tuned Tandem Column ConceptAnalytical Chemistry, 2001
- Method development for the determination of anthocyanins in red wines by high-performance liquid chromatography and classification of German red wines by means of multivariate statistical methodsJournal of Chromatography A, 2000
- Capillary electrophoresis methods development and sensitivity enhancement strategies for the separation of industrial and environmental chemicalsJournal of Chromatography A, 1996
- Temperature program optimization by computer simulation for the capillary GC analysis of fatty acid methyl esters on biscyanopropyl siloxane phasesJournal of High Resolution Chromatography, 1993