The Effects of Residual Hearing in Traditional Cochlear Implant Candidates After Implantation With a Conventional Electrode
- 1 April 2013
- journal article
- cochlear implants
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 34 (3) , 516-521
Abstract
Objective To analyze the effects of residual hearing on postoperative speech performance in traditional cochlear implant (CI) patients implanted with a conventional electrode. Study Design Retrospective review. Setting Academic tertiary referral center. Patients A total of 129 adults implanted by a single surgeon at a tertiary care facility between June 2005 and November 2010 with measurable preoperative pure tone thresholds at any frequency were included. Intervention Cochlear implantation with a conventional electrode via an anterior inferior cochleostomy. Main Outcome Measure Speech perception using monosyllabic word scores in quiet and sentences in quiet and noise in the electric (CI-only) condition of the implanted ear. Preservation of hearing was defined as complete for postoperative thresholds within 10 dB of preimplant values and partial if greater than 11 dB. Pure tone audiometry and speech perception testing were performed preoperatively and at regular intervals postoperatively, with the 1-year evaluation being the final outcome period. Results Preservation at any frequency or level was not a factor in speech perception outcome, although preservation was more common in low frequencies. Hearing preservation was correlated with younger age at implantation, but was not related to length of hearing loss, cause of deafness, device type, sex, preoperative speech performance, or low-frequency pure-tone average. Conclusion Hearing can be preserved in traditional CI patients implanted with a conventional electrode. Although preservation of hearing may have implications for future technology, it is not currently correlated with speech performance in the CI-only condition.Keywords
This publication has 24 references indexed in Scilit:
- Spectral and Temporal Measures in Hybrid Cochlear Implant UsersOtology & Neurotology, 2012
- Implications of Minimizing Trauma During Conventional Cochlear ImplantationOtology & Neurotology, 2011
- Impact of Hair Cell Preservation in Cochlear ImplantationOtology & Neurotology, 2010
- Residual Hearing Preservation After Pediatric Cochlear ImplantationOtology & Neurotology, 2010
- Histopathologic Assessment of Fibrosis and nEw Bone Formation in Implanted Human Temporal Bones Using 3D ReconstructionOtolaryngology–Head and Neck Surgery, 2009
- Hybrid 10 Clinical TrialAudiology and Neurotology, 2009
- Hearing Conservation Surgery Using the Hybrid-L ElectrodeAudiology and Neurotology, 2009
- Quantitative Evaluation of New Bone and Fibrous Tissue in the Cochlea following Cochlear Implantation in the HumanAudiology and Neurotology, 2007
- A Model for Cochlear Implant Electrode Insertion and Force Evaluation: Results with a New Electrode Design and Insertion TechniqueThe Laryngoscope, 2005
- Surgical implications of perimodiolar cochlear implant electrode design: avoiding intracochlear damage and scala vestibuli insertionCochlear Implants International, 2001