Cerebral hemodynamics with intra-aortic balloon pump: business as usual?
- 22 June 2017
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 38 (7) , 1349-1361
Abstract
Objective: Intra-aortic balloon pump (IABP) is commonly used as mechanical support after cardiac surgery or cardiac shock. Although its benefits for cardiac function have been well documented, its effects on cerebral circulation are still controversial. We hypothesized that transfer function analysis (TFA) and continuous estimates of dynamic cerebral autoregulation (CA) provide consistent results in the assessment of cerebral autoregulation in patients with IABP. Approach: Continuous recordings of blood pressure (BP, intra-arterial line), end-tidal CO2, heart rate and cerebral blood flow velocity (CBFV, transcranial Doppler) were obtained (i) 5 min with IABP ratio 1:3, (ii) 5 min, starting 1 min with the IABP-ON, and continuing for another 4 min without pump assistance (IABP-OFF). Autoregulation index (ARI) was estimated from the CBFV response to a step change in BP derived by TFA and as a function of time using an autoregressive moving-average model during removal of the device (ARI t ). Critical closing pressure and resistance area-product were also obtained. Main results: ARI with IABP-ON (4.3 ± 1.2) were not different from corresponding values at IABP-OFF (4.7 ± 1.4, p = 0.42). Removal of the balloon had no effect on ARI t , CBFV, BP, cerebral critical closing pressure or resistance area-product. Significance: IABP does not disturb cerebral hemodynamics. TFA and continuous estimates of dynamic CA can be used to assess cerebral hemodynamics in patients with IABP. These findings have important implications for the design of studies of critically ill patients requiring the use of different invasive support devices.Keywords
This publication has 36 references indexed in Scilit:
- IABP before cardiac surgery: clinical benefit compared to intraoperative implantationPerfusion, 2012
- Cognitive Trajectories after Postoperative DeliriumThe New England journal of medicine, 2012
- Reproducibility of cerebral and peripheral haemodynamic responses to active, passive and motor imagery paradigms in older healthy volunteers: A fTCD studyJournal of Neuroscience Methods, 2012
- Dynamic cerebral autoregulation: different signal processing methods without influence on results and reproducibilityMedical & Biological Engineering & Computing, 2010
- Intraaortic Balloon Pump Counterpulsation and Cerebral Autoregulation: an observational studyBMC Anesthesiology, 2010
- Cerebral Autoregulation: From Models to Clinical ApplicationsCardiovascular Engineering, 2007
- Comparison of Static and Dynamic Cerebral Autoregulation MeasurementsStroke, 1995
- Cerebral Autoregulation Dynamics in Premature NewbornsStroke, 1995
- Reversed intracranial blood flow in patients with an intra-aortic balloon pump.Stroke, 1990
- Cerebral autoregulation dynamics in humans.Stroke, 1989