Cross‐vendor harmonization of T2‐relaxation‐under‐spin‐tagging (TRUST) MRI for the assessment of cerebral venous oxygenation
Authors:
- 25 January 2018
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 80 (3) , 1125-1131
Abstract
Purpose: Cerebral venous oxygenation (Yv) is an important physiological parameter and has potential clinical application in many brain diseases. T2‐relaxation‐under‐spin‐tagging (TRUST) is a commonly used MRI method to measure Yv. Harmonization of this technique across MRI vendors is important for dissemination and multicenter studies of brain oxygenation and metabolism as a disease biomarker.Methods: TRUST pulse sequence components and imaging parameters were carefully matched between two major MRI vendors, Philips and Siemens. Each subject (N = 10) was scanned on both scanners within a 2.5‐h period. On each scanner, the subject was scanned in two sessions to assess intersession reproducibility. A hyperoxia challenge was also included in both sessions and on both scanners to evaluate the sensitivity of the technique to Yv changes. Measured Yv values, confidence interval of Yv estimates ( ), as well as intrasession and intersession coefficient of variation (CoV) of Yv, were compared between the two scanners.Results: Yv measured on the two vendors were highly compatible and strongly correlated (R2 = 0.957). Yv changes associated with hyperoxia challenge were significant on both scanners (P < 0.001) and were also correlated across scanners (P = 0.007). Intrasession and intersession CoV of measured Yv were less than 3% and showed no difference between scanners. were less than 1% on both scanners and showed no difference between scanners when echo times were matched on the two scanners.Conclusion: This work suggests that harmonized TRUST MRI can yield highly compatible Yv measurements across different vendors. Magn Reson Med 80:1125–1131, 2018. © 2018 International Society for Magnetic Resonance in Medicine.Keywords
Funding Information
- NIH (R01 MH084021, R01 NS067015, R01 AG042753, R01 AG047972, R21 NS095342, R21 NS085634, P41 EB015909)
This publication has 50 references indexed in Scilit:
- Elevated global cerebral blood flow, oxygen extraction fraction and unchanged metabolic rate of oxygen in young adults with end-stage renal disease: an MRI studyEuropean Radiology, 2015
- Multi-vendor reliability of arterial spin labeling perfusion MRI using a near-identical sequence: Implications for multi-center studiesNeuroImage, 2015
- MultiCenter Reliability of Diffusion Tensor ImagingBrain Connectivity, 2012
- Intra- and interscanner variability of automated voxel-based volumetry based on a 3D probabilistic atlas of human cerebral structuresNeuroImage, 2010
- Quantitative BOLD: Mapping of human cerebral deoxygenated blood volume and oxygen extraction fraction: Default stateMagnetic Resonance in Medicine, 2006
- Between session reproducibility and between subject variability of diffusion MR and tractography measuresNeuroImage, 2006
- MR susceptometry for measuring global brain oxygen extractionMagnetic Resonance in Medicine, 2006
- Decreased medial temporal oxygen metabolism in Alzheimer's disease shown by PET.1996
- Evidence of misery perfusion and risk for recurrent stroke in major cerebral arterial occlusive diseases from PET.Journal of Neurology, Neurosurgery & Psychiatry, 1996
- Focal physiological uncoupling of cerebral blood flow and oxidative metabolism during somatosensory stimulation in human subjects.Proceedings of the National Academy of Sciences, 1986