Effectiveness of Dry Eye Therapy Under Conditions of Environmental Stress
Authors:
- Alan TomlinsonATAlan Tomlinson
- Louise C. MaddenLMLouise C. Madden
- Peter A. SimmonsPSPeter A. Simmons
Open Access
- 7 January 2013
- journal article
- research article
- Published by Taylor & Francis in Current Eye Research
- Vol. 38 (2) , 229-236
Abstract
Dry eye is often characterized by increased tear evaporation due to poor tear film quality, especially of the lipid component of the tear film. Using an environmental chamber to induce environmental stress, this study compared the effect of three lubricant eye drops on various aspects of tear physiology in a crossover design (evaporation was the principal outcome measure). Three eye drop formulas were tested: 0.5% carmellose sodium (Drop C), 0.5% carmellose sodium with added lipid (Drop C-L) and 1.0% glycerine with added lipid (Drop G-L). Nineteen control and 18 dry eye subjects used each product for 2 weeks, three times per day, in a random order, with a minimum 1-week washout between treatment periods. Tear evaporation, break up time, osmolarity, tear structure (by interferometry) and patient symptoms were assessed with the subjects adapted for 10 min in an environmental chamber controlled at 20% relative humidity and 22 °C. The treatment effects were analyzed using general linear model repeated measures analyses of variance. In dry eye subjects, evaporation, break up time, osmolarity and symptoms improved for all formulas (p < 0.05). Normal subjects showed some improvements: evaporation with C-L, osmolarity with C and symptoms with C-L and G-L. Change in evaporation was greater for both C-L and G-L versus C (p < 0.05), and there was a trend for C-L to reduce evaporation more than G-L (p < 0.11). There were no significant treatment effects on tear film structure. Overall, the eye drop formula containing both carmellose sodium and lipid (C-L) produced a greater treatment effect on tear evaporation than the other formulations containing only one of these ingredients. This study also demonstrates the utility of a controlled environmental chamber in showing the difference in performance between dry eye treatments.Keywords
This publication has 39 references indexed in Scilit:
- Effect of Humidity Variations in a Controlled Environment Chamber on Tear Evaporation After Dry Eye TherapyEye & Contact Lens: Science & Clinical Practice, 2013
- Distribution of Aqueous-Deficient and Evaporative Dry Eye in a Clinic-Based Patient CohortCornea, 2012
- Effectiveness of Artificial Tears in the Management of Evaporative Dry EyeCornea, 2012
- The International Workshop on Meibomian Gland Dysfunction: Report of the Subcommittee on Management and Treatment of Meibomian Gland DysfunctionInvestigative Ophthalmology & Visual Science, 2011
- Tear Physiology of Aqueous Deficiency and Evaporative Dry EyeOptometry and Vision Science, 2009
- Impact on Ocular Surface Evaporation of an Artificial Tear Solution Containing Hydroxypropyl GuarEye & Contact Lens: Science & Clinical Practice, 2008
- Clinical Performance of a Mid-Viscosity Artificial Tear for Dry Eye TreatmentCornea, 2007
- Comparison of the Efficacy of Two Lipid Emulsion Eyedrops in Increasing Tear Film Lipid Layer ThicknessEye & Contact Lens: Science & Clinical Practice, 2007
- Performance profile of sodium hyaluronate in patients with lipid tear deficiency: randomised, double-blind, controlled, exploratory studyBritish Journal of Ophthalmology, 2006
- Human tear film pre‐rupture phase time (TP‐RPT)‐A non‐invasive technique for evaluating the pre‐corneal tear film using a novel keratometer mireOphthalmic and Physiological Optics, 1989