Delay-and-Sum Consistent Wavenumber Algorithm
- 24 February 2026
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. 73 (3) , 379-390
Abstract
Fourier-domain beamforming methods offer a computationally efficient alternative to time domain methods in ultrasound imaging. Among these, the wavenumber algorithm (WA) achieves fast image reconstruction from full-matrix capture (FMC) data but introduces amplitude distortions due to its inherent weighting. In this study, we present a modified Fourier-domain beamforming method that operates on FMC data and reproduces the amplitude response of the conventional delay-and-sum (DAS) method while maintaining the computational efficiency of WA. This is achieved through a derivation of a correction factor that restores DAS-like amplitude characteristics in WA. The correction is implemented in two stages, consisting of a matrix multiplication to the data in the Fourier domain and a subsequent scaling with the z coordinate in the reconstructed image. Validation on simulated point targets, phantom experiment, and in-vivo imaging demonstrates that the proposed method produces images nearly indistinguishable from DAS but with significantly reduced computational burden. We also investigate the role of zero-padding, showing how interpolation accuracy affects reconstruction fidelity and computational efficiency. The proposed approach can, for example, facilitate the development of ultrasound systems with reduced power consumption.Keywords
This publication has 32 references indexed in Scilit:
- Real-time 3D imaging with Fourier-domain algorithms and matrix arrays applied to non-destructive testingUltrasonics, 2022
- Application of a Range-Doppler Algorithm to Frequency-Domain Beamforming of Ultrasound Signals2020
- Interpolation-Free Stolt Mapping for SAR ImagingIEEE Geoscience and Remote Sensing Letters, 2013
- Real-time full matrix capture for ultrasonic non-destructive testing with acceleration of post-processing through graphic hardwareNDT & E International, 2012
- Post-processing of the full matrix of ultrasonic transmit–receive array data for non-destructive evaluationNDT & E International, 2005
- Wavenumber domain reconstruction of SAR/SAS imagery using single transmitter and multiple-receiver geometryElectronics Letters, 2002
- Experimental study of high frame rate imaging with limited diffraction beamsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1998
- 2D and 3D high frame rate imaging with limited diffraction beamsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1997
- Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducersIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1992
- A Computational Study of Reconstruction Algorithms for Synthetic Aperture Diffraction Tomography: Interpolation Versus Interpolation-Free1988