Adverse Events Associated With 10-kHz Dorsal Column Spinal Cord Stimulation
Authors:
- 8 February 2022
- journal article
- research article
- Published by Wolters Kluwer Health in The Clinical Journal of Pain
- Vol. 38 (5) , 320-327
Abstract
Background: High-frequency (10-kHz) spinal cord stimulation (SCS) continues to be an emerging therapy in chronic pain management. The same complications that plagued earlier SCS systems may affect newer stimulation technologies, although there is limited data on the type of complications and surgical management of these complications. Objective: The aim of this study was to systematically examine real-world complications associated with 10-kHz SCS reported on the Manufacturer and User Facility Device Experience (MAUDE) database. Materials and Methods: The MAUDE database was queried for entries reported between January 1, 2016 and December 31, 2020. Entries were classified into procedural complications, device-related complications, patient complaints, surgically managed complications, serious adverse events, and/or other complications. Primary outcomes included type and frequency of complications, and surgical management of complications. Results: A total of 1651 entries were analyzed. Most entries were categorized as procedural complications (72.6%), followed by serious adverse events (10.5%), device-related complications (10.5%), and patient complaints (9.9%). Most complications were managed surgically with explant (50.9%) rather than revision (5.0%) or incision/drainage (6.6%). Of procedural complications, the most common entries included non-neuraxial infection (52.9%), new neurological symptoms (14.7%), and dural puncture (9.5%). Of device-related complications, the most common entries included lead damage (41.6%), erosion (18.5%), and difficult insertion (11.5%). Conclusion: This retrospective 5-year analysis of complications from10-kHz SCS provides a real-world assessment of safety data unique for this stimulation modality. This analysis may help inform future clinical decisions, lead to device enhancement and optimization, and improve mitigation of risks to provide safe and efficacious use of 10-kHz SCS.Keywords
This publication has 32 references indexed in Scilit:
- Treatment-Limiting Complications of Percutaneous Spinal Cord Stimulator Implants: A Review of Eight Years of Experience From an Academic Center DatabaseNeuromodulation: Technology at the Neural Interface, 2015
- Spinal Cord Stimulation is Safe and Feasible in Patients with Advanced Heart Failure: Early Clinical ExperienceEuropean Journal of Heart Failure, 2014
- Outcomes of Percutaneous and Paddle Lead Implantation for Spinal Cord Stimulation: A Comparative Analysis of Complications, Reoperation Rates, and Health-Care CostsNeuromodulation: Technology at the Neural Interface, 2013
- Percutaneous Implanted Paddle Lead for Spinal Cord Stimulation: Technical Considerations and Long-Term Follow-UpNeuromodulation: Technology at the Neural Interface, 2012
- Spinal Cord Stimulation in Pain Management: A ReviewThe Korean Journal of Pain, 2012
- Incidence and Avoidance of Neurologic Complications with Paddle Type Spinal Cord Stimulation LeadsNeuromodulation: Technology at the Neural Interface, 2011
- Spinal cord stimulation versus conventional medical management for neuropathic pain: A multicentre randomised controlled trial in patients with failed back surgery syndromePain, 2007
- Prevention of Mechanical Failures in Implanted Spinal Cord Stimulation SystemsNeuromodulation: Technology at the Neural Interface, 2006
- A Review of Complications Associated with Vertebroplasty and Kyphoplasty as Reported to the Food and Drug Administration Medical Device Related Web SiteJournal of Vascular and Interventional Radiology, 2004
- Electrical Inhibition of Pain by Stimulation of the Dorsal ColumnsAnesthesia & Analgesia, 1967