Protective spur dike for scour mitigation of existing spur dikes
- 4 October 2011
- journal article
- research article
- Published by Taylor & Francis in Journal of Hydraulic Research
- Vol. 49 (6) , 809-813
Abstract
To alleviate the scour depth around a series of existing spur dikes (SDs), a protective SD located upstream of the first was experimentally investigated. To determine the optimal design parameters, various values, lengths, angles and the spacing of a protective SDs were experimentally tested under different clear-water conditions in a straight river reach and a fixed flow depth. To investigate the behaviour of the flow field around the SDs, acoustic Doppler velocimeter was used to measure instantaneous velocity components on a rough rigid bed. The results indicate that a properly designed protective SD is able to decrease the average of the maximum scour depth around the main SDs. The optimum design parameters of a protective SD are recommended for each length for a particular experiment.Keywords
This publication has 6 references indexed in Scilit:
- Spur Failure in River EngineeringJournal of Hydraulic Engineering, 2008
- Parallel Walls as an Abutment Scour CountermeasureJournal of Hydraulic Engineering, 2006
- 3D Unsteady RANS Modeling of Complex Hydraulic Engineering Flows. II: Model Validation and Flow PhysicsJournal of Hydraulic Engineering, 2005
- Clear-water scour development at bridge abutmentsJournal of Hydraulic Research, 2003
- Scour around spur dikes and bridge abutmentsJournal of Hydraulic Research, 2001
- Maximum local scour depth at bridge piers and abutmentsJournal of Hydraulic Research, 1998