Abstract
In this paper, we proposed an effective method for detecting fiducial points in arterial blood pressure pulses. An arterial blood pressure pulse normally consists of onset, systolic peak and dicrotic notch. Detection of fiducial points in blood pressure pulses is a critical task and has many potential applications. The proposed method employs empirical wavelet transform for locating the systolic peak and onset of blood pressure pulse. The proposed method first estimates the fundamental frequency of blood pressure pulse using empirical wavelet transform and utilizes the combination of the blood pressure pulse and the estimated frequency for locating onset and systolic peak. For dicrotic notch detection, it utilizes the first-order difference of blood pressure pulse. The algorithm was validated on various open-source databases and was tested on a data set containing 12,230 beats. Two benchmark parameters such as sensitivity and positive predictivity were used for the performance evaluation. The comparison results for accuracy of the detection of systolic peak, onset and dicrotic notch are reported. The proposed method attained a sensitivity and positive predictivity of 99.95% and 99.97%, respectively, for systolic peaks. For onsets, it attained a sensitivity and predictivity of 99.88% and 99.92%, respectively. For dicrotic notches, a sensitivity and positive predictivity of 98.98% and 98.81% were achieved, respectively.Keywords
This publication has 16 references indexed in Scilit:
- Robust detection of heart beats in multimodal dataPhysiological Measurement, 2015
- Short-term heart rate variability—age dependence in healthy subjectsPhysiological Measurement, 2012
- On an automatic delineator for arterial blood pressure waveformsBiomedical Signal Processing and Control, 2010
- Reducing false alarm rates for critical arrhythmias using the arterial blood pressure waveformJournal of Biomedical Informatics, 2008
- Development of a mobile pulse waveform analyzer for cardiovascular health monitoringComputers in Biology and Medicine, 2008
- An Automatic Beat Detection Algorithm for Pressure SignalsIEEE Transactions on Biomedical Engineering, 2005
- A real-time algorithm for the quantification of blood pressure waveformsIEEE Transactions on Biomedical Engineering, 2002
- Advancements in estimating baroreflex functionIEEE Engineering in Medicine and Biology Magazine, 2001
- How to measure baroreflex sensitivityJournal Of Hypertension, 2000
- Heart rate variability: Standards of measurement, physiological interpretation, and clinical useEuropean Heart Journal, 1996